background image

·

 

09

10 ·

WARNING AND SAFETY NOTES  

Standard Battery Parameters

3.7V/cell

3.6V/cell

3.3V/cell

1.2V/cell

1.2V/cell

2.0V/cell

4.2V/cell

4.1V/cell

3.6V/cell

1.5V/cell

1.5V/cell

2.46V/cell

3.8V/cell

3.7V/cell

3.3V/cell

n/a

n/a

n/a

3.0V/cell

2.5V/cell

2.0V/cell

0.85V/cell

1.0V/cell

1.75V/cell

Nominal Voltage

Min. Discharge Voltage

LiPo

Max Charge Voltage
Storage Voltage

LiIon

LiFe

NiCd

MiMH

Pb

Be very careful to choose the correct voltage for different types of battery otherwise you may cause damage
to the batteries.  Incorrect settings could cause the cells to fire or explode.

WARNING AND SAFETY NOTES  

During charge process, a specific quantity of electrical energy is fed into the battery. The charge quantity is 
calculated  by  multiplying  charge  current  by  charge  time.  The  maximum  permissible  charge  current  varies 
depending  on  the  battery  type  or  its  performance,  and  can  be  found  in  the  information  by  the  battery 
manufacturer.  Only  batteries  that  are  expressly  stated  to  be  capable  of  quick-charge  are  allowed  to  be 
charged at rates higher than the standard charge current.

Charging 

Did you select the appropriate program suitable for the type of battery you are  charging?
Did you set up adequate current for charging or discharging?
Have you checked the battery voltage? Lithium battery packs can be wired in parallel and 
in series, i.e. a 2 cell pack can be 3.7V (in parallel) or 7.4V (in series).
Have you checked that all connections are firm and secure? 
Make sure there are no intermittent contacts at any point in the circuit.

Please bear in mind the following points before commencing charging:

A battery pack which consists of different types of cells (including different manufacturers)
A battery that is already fully charged or just slightly discharged.
Non-rechargeable batteries (Explosion hazard).
Batteries that are require a different charge technique from NiCd, NiMh, LiPo or Gel cell 
(Pb, Lead acid).
A faulty or damaged battery.
A battery fitted with an integral charge circuit or a protection circuit.
Batteries installed in a device or which are electrically linked to other components.
Batteries that are not expressly stated by the manufacturer to be suitable for the currents 
the charger delivers during the charge process.

Never attempt to charge or discharge the following types of batteries.

Ultimate 400W

Ultimate 400W

Summary of Contents for Ultimate 400W 20AMP

Page 1: ...1 All specifications and figures are subject to change without notice Professional Balance Charger Discharger Professional Balance Charger Discharger SkyRC Technology Co Ltd 2011 Manufactured by SKYRC...

Page 2: ...with battery management and integral balancer The unit is simple to use but the operation of a sophisticated automatic charger such as the does require some knowledge on the part of the user These ope...

Page 3: ...t in company with a specialist INTRODUCTION Left View Right View Ventilation Fan DC input 12V 18V Temperature Probe Socket Positive Charger Output Universal Balancing Port Pitch 2 54mm Ventilation Fan...

Page 4: ...arging During the process of discharging Ultimate 400W can monitor and balance each cell of the battery individually Error message will be indicated and the process will be ended automatically if the...

Page 5: ...unattended when it is connected to its power supply If any malfunction is found Terminate THE PROCESS AT ONCE and refer to the operation manual Keep the charger well away from dust damp rain heat dir...

Page 6: ...arge current Charging Did you select the appropriate program suitable for the type of battery you are charging Did you set up adequate current for charging or discharging Have you checked the battery...

Page 7: ...to charge in series WARNING AND SAFETY NOTES The main purpose of discharging is to clean residual capacity of the battery or to reduce the battery voltage to a defined level The same attention should...

Page 8: ...Continue on next page 13 14 PROGRAM FLOW CHART PROGRAM FLOW CHART Ultimate 400W Ultimate 400W...

Page 9: ...ial to check one last time that you have set the parameters correctly If the settings are incorrect the battery may be damaged and could even burst into flames or explode To avoid short circuits betwe...

Page 10: ...cess can be finished within the time term with the erroneous cell count This may cause the fatal result If the processor recognizes the cell count incorrectly at the beginning of charge or discharge p...

Page 11: ...BATTERY LILON LIPO LIFE PROGRAM Lithium battery LiIon LiPo LiFe program These programs are only suitable for charging and discharging Lithium batteries with a nominal voltage of 3 3V 3 6V and 3 7V per...

Page 12: ...g the voltage of Lithium polymer battery cells while charging In the balance mode the battery needs to have a balance lead to connect to the individual balance port of the charger And you need to conn...

Page 13: ...h numbers are identical you can start charging by press START ENTER button If not press BATT TYPE STOP button to go back to previous screen to carefully check the number of cells of the battery pack b...

Page 14: ...connection you can see the error message and press INC to know which cell is damaged CHARGING NICD NIMH BATTERY IN THE CHARGE MODE DEC Batt type Stop Elapsed time INC DEC Start Enter INC Charged capac...

Page 15: ...START ENTER key for more than 3 seconds to start the program 3 seconds CHARGE DISCHARGE AND DISCHARGE CHARGE CYCLE OF NICD NIMH BATTERY Charge discharge and discharge charge cycle of NiCd NiMH battery...

Page 16: ...Charge current Battery voltage DEC Start Enter INC Charged capacity 3 seconds Set up the charge current on the left and nominal voltage on the right Range of current is 0 1 20A the voltage should matc...

Page 17: ...our convenience Ultimate 400W has a data storage and load program It can store ten batteries data representing the respective specifications of batteries You can call back the data when charging or di...

Page 18: ...rious functions of protective and monitoring the system to verify functions and the state of its electronics In any case of occurring error the screen displays the cause of error that is self explanat...

Page 19: ...symbol means that you must dispose of electrical from the General household waste when it reaches the end of its useful life Take your charger to your local waste collection point or recycling centre...

Page 20: ...20 0 20 0 20 0 20 0 20 0 20 0 20 0 20 0 20 0 20 0 19 0 18 0 20 0 20 0 20 0 20 0 20 0 20 0 18 0 16 0 3 6 7 2 10 8 14 4 18 0 21 6 3 0 4 5 6 0 7 5 9 0 10 5 12 0 13 5 15 0 16 5 18 0 19 5 21 0 22 5 7 4 9...

Page 21: ...ay compensation regardless of the legal argument employed is limited to the invoice value of those SkyRC products which were immediately and directly involved in the event in which the damage occurred...

Page 22: ...1C current value of 600mA and a 3C current value of 3 x 600mA 1800mA or 1 8A The 1C current value for a 3200mAh battery would be 3200mA 3 2A We guarantee this product to be free of manufacturing and a...

Reviews: