33
34 ·
VARIOUS INFORMATION IN THE PROGRAM
Various information in the program
C 5 : 4 . 1 8 C 6 : 4 . 1 5 V
C 7 : 0 . 0 0 C 8 : 0 . 0 0 V
It comes to the final voltage when the program ended.
Displayed temperature cut-off function is turn on.
The external temperature is displayed when the temperature probe is used.
Present input voltage.
Displayed safety timer is turn on and duration of time in minutes.
Displayed capacity cut-off function is turn on and the setting value of capacity.
The battery is connected with balance lead. You can check voltage of each cell in the
battery pack.
You can inquire the variety of information during the process of charging and discharging on the LCD
screen.Press DEC key, the charger will display users’ setting. You can press INC key to monitor voltage of
each cell while the batteries balance lead is connected to the charger.
WARNING AND ERROR MESSAGE
Ultimate 400W incorporates a various functions of protective and monitoring the system to verify functions
and the state of its electronics. In any case of occurring error, the screen displays the cause of error that is
self-explanatory with audible sound.
Incorrect polarity connected.
Battery connection is interrupted.
Short-circuit of the output termination.
Input voltage wrong.
The voltage of the battery pack has been selected incorrectly!
The charger has malfunctioned for some reason. Seek professional advice.
The voltage is lower than which is set. Please check the number of cells in the battery pack.
The processor cannot control the feeding current, please repair it.
Wrong connection of the connector detected; please check the connector and cable.
Voltage of one cell in the battery pack is too high; please check the voltage of each cell.
Voltage of one cell in the battery pack is too low; please check the voltage of each cell.
The voltage is higher than which is set. Please check the number of cells in the battery pack.
The internal temperature of the unit goes too high. Cool down the unit.
Ultimate 400W