18
6. Maintenance
The maintenance must be a group of procedures that have the objective of keeping the
appliance in its best condition of operation and increasing its life expectancy and safety.
* Cleaning – Check the item 3.3 Cleaning of this Manual.
* Electrical wiring – Check all the cables to avoid deterioration and all the electrical contacts
about their tightening and corrosion.
* Contacts – Turn on and off bottom, emergency bottom, reset bottom, electric circuits,
etc. Check the appliance so that all the components are working correctly and that the
operation is working normally.
* Installation – Check the installation of your appliance according to the item 2.1 Installation
of this manual.
1 - Items to be verified and implemented monthly:
- Check the electrical installation;
- Check the outlet tension;
- Measure the operating current and compare it to the Nominal one;
- Check all the eletrical terminal tightening of the appliance, to avoid bad contact;
- Check the possible clearance of the shift of the electric motor;
- Check the wiring and the electric cable to avoid its overheating, deficient isolation and
mechanical breakdown.
2 - Items to be verified and implemented every 3 months:
- Check the electric components as ON/OFF Switch, Emergency Button, Reset Switch, and
eletric circuit related to overheating, deficient isolation and mechanical breakdown.
- Check possible loosens in the bearings
- Check retainers, o´rings, v´rings and other sealing systems.
3 - Fixing distance of the bulb support (Fig. 06), in millimeters: