213210AAAA
SJ46 AJ, SJ51 AJ, SJ63 AJ
52
Section 4 – Inspections Before Operation
Function tests
4.3-9 Do a test of the footswitch and all
the boom and platform functions
1.
Make sure the
emergency-stop
button is pulled
out.
2.
Make sure the
engine start/on/off
switch is in
the on position.
3.
Do not start the engine.
4.
Move the
generator
switch
2
(optional
equipment) to the off position.
5.
Press and hold the
footswitch
3
and select
the start position from the
engine start/on/off
switch to try to start the engine.
▪
Result:
The engine does not start.
6.
Do not press the
footswitch
, and try to start the
engine.
▪
Result:
The engine starts.
7.
Do not press the
footswitch
, and do a test
of each boom and platform function with the
engine on.
▪
Result:
The MEWP functions do not operate.
NOTE
A 15-second anti-tiedown feature prevents the
footswitch operation when the operator presses
it for 15 seconds without the activation of a
function.
8.
Press and hold the
footswitch
, and do a test
of all the boom and platform functions with the
engine on.
▪
Result:
All MEWP functions operate.
TM
1
2
+
+
A
2
3
Summary of Contents for SJ46 AJ
Page 1: ...OPERATION MANUAL SJ46 AJ SJ51 AJ SJ63 AJ ARTICULATING BOOMS 213210AAAA December 2019 AS...
Page 4: ...213210AAAA SJ46 AJ SJ51 AJ SJ63 AJ 4 Notes...
Page 14: ...213210AAAA SJ46 AJ SJ51 AJ SJ63 AJ 14 Notes...
Page 20: ...213210AAAA SJ46 AJ SJ51 AJ SJ63 AJ 20 Notes...
Page 76: ...213210AAAA SJ46 AJ SJ51 AJ SJ63 AJ 76 Notes...
Page 77: ...SJ46 AJ SJ51 AJ SJ63 AJ 213210AAAA 77 Section 7 Technical Diagrams and Specifications...
Page 118: ...213210AAAA SJ46 AJ SJ51 AJ SJ63 AJ 118 Notes...
Page 119: ......
Page 120: ...www skyjack com...