Function tests
Section 4 – Inspections Before Operation
4.3-23 Do a test of the oscillating cylinders
WARNING
Fall hazard. Do not operate the controls on the
platform control console without the correct fall-
protection attached to the designated location in
the platform. If you do not obey, there is a risk of
death or serious injury.
1.
Make sure the MEWP is on a firm, level surface.
2.
Extend the boom 30 cm (12 in).
▪
Result:
The steer axle oscillation locks
17
.
3.
Drive one of the steer tires onto a 15 cm (6 in)
block or curb.
▪
Result:
The MEWP chassis tilts.
4.
Retract the boom.
▪
Result:
The steer axle oscillation unlocks
16
.
The MEWP chassis is now level.
4.3-24 Do a test of the wire ropes
(SJ61 T+/SJ66 T+ only)
1.
Raise the main boom to approximately
horizontal.
2.
Extend and retract the boom sections.
▪
Result:
There is no delay in the movement of
the boom section.
16
17
Summary of Contents for SJ40 T+
Page 4: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 4 Notes ...
Page 10: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 10 Notes ...
Page 14: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 14 Notes ...
Page 22: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 22 Notes ...
Page 40: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 40 Notes ...
Page 64: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 64 Notes ...
Page 72: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 72 Notes ...
Page 83: ...SJ40 T SJ45 T SJ61 T SJ66 T 213201ACA 83 Section 7 Technical Diagrams and Specifications ...
Page 126: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 126 Notes ...
Page 128: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 128 Notes ...
Page 129: ...Cancer and Reproductive Harm https www p65warnings ca gov WARNING ...
Page 130: ...www skyjack com ...