Floor loading pressure
7.8 Floor loading pressure
Model
Weights
Pressures
MEWP Weight
Max Weight per
Wheel**
LCP***
OFL***
kg
lb
kg
lb
kPa
psi
kPa
psf
SJ40 T+
Min*
6,410
14,130
1,905
4,200
857
124
8.6
180
Max*
6,865
15,130
3,495
7,700
1,223
177
9.2
192
SJ45 T+
Min*
7,170
15,780
2,041
4,500
710
103
9.3
195
Max*
7,610
16,780
4,082
9,000
1,163
169
9.9
207
SJ61 T+
Min*
11,375
25,075
3,515
7,750
1,053
153
13.4
280
Max*
11,830
26,075
6,125
13,500
1,578
229
14.0
291
SJ66 T+
Min*
12,485
27,525
3,675
8,100
1,044
151
14.7
307
Max*
12,940
28,525
6,800
15,000
1,711
248
15.3
319
1963AB
*
Min:
Minimum MEWP weight (Unloaded platform, no options/attachments)
Max:
Maximum MEWP weight (Platform loaded to capacity with options/attachments)
**
Wheel Load
is the weight that can be experienced on one wheel.
Note:
This is more than 25% of the machine weight due to possible weight distribution over the machine and platform.
***
LCP:
Local Concentrated Pressure is a measure of how hard the MEWP presses on the area in direct contact with the floor/tire.
OFL:
Overall Floor Load (Pressure) is a measure of the average load the MEWP imparts on the whole surface directly underneath
the chassis. This has been calculated by dividing the MEWP weight by the overall floor area occupied by the MEWP (on wheels).
Note:
The floor covering (e.g., tile, carpet, etc.) or the structure (e.g., beams) of the operating surface must be able to withstand
more than the values indicated above.
NOTE
The
LCP
or
OFL
that an individual surface can withstand varies from structure to structure and is
generally determined by the engineer or architect for that particular structure.
Summary of Contents for SJ40 T+
Page 4: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 4 Notes ...
Page 10: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 10 Notes ...
Page 14: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 14 Notes ...
Page 22: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 22 Notes ...
Page 40: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 40 Notes ...
Page 64: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 64 Notes ...
Page 72: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 72 Notes ...
Page 83: ...SJ40 T SJ45 T SJ61 T SJ66 T 213201ACA 83 Section 7 Technical Diagrams and Specifications ...
Page 126: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 126 Notes ...
Page 128: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 128 Notes ...
Page 129: ...Cancer and Reproductive Harm https www p65warnings ca gov WARNING ...
Page 130: ...www skyjack com ...