Optional equipment and attachments
Section 3 – Familiarization
1
Orange indicator:
This light shows that the
access control unit is ON. The keypad always
has power regardless of the emergency-stop,
off/base/platform key switch, or main power
disconnect position.
2
Green/red indicator:
A green light shows that
the access control unit is in operation. A red light
that flashes shows that the keypad received a
cancel input.
Operation
To operate the MEWP, the light and all of these power
connections must be ON before the set time expires.
This set time is the time that the MEWP owner sets for
the access control operation.
▪
The green light on the keypad of the access
control unit.
▪
The main power disconnect switch.
▪
The emergency-stop button on the base control
console.
▪
The off/base/platform key switch.
You can also set these power connections to ON
before you start the access control unit.
To operate the access control unit, use the PIN code
or Smart ID card.
With the Keypad:
NOTE
This touch-sensitive keypad beeps to identify a
correct input.
1.
Enter the PIN code.
2.
Press the
green checkmark
to confirm.
▪
Result:
The green light identifies an approved
ID. Start the operation.
NOTE
If you push an incorrect button when you enter
the PIN code, push the Cancel button to start
again.
With the Smart ID Card:
1.
Put the card in front of the reader.
2.
A beep identifies that the reader read the
card.
▪
Result:
The green light identifies an
approved ID. Start the operation.
IMPORTANT
If the set time of the access control unit expires,
enter the PIN code or tap the Smart ID card again.
If there is a failure of the access control activation,
speak to the MEWP owner.
IMPORTANT
The access control unit will not operate if these
power connections are not ON in the set time, or if
the operator disconnects them:
▪
The main power disconnect switch
▪
The emergency-stop button on the base
control console
▪
The off/base/platform key switch.
IMPORTANT
To start the access control unit, enter the PIN
code or tap the Smart ID card. These power
connections must be in the ON position in the set
time:
▪
The main power disconnect switch
▪
The emergency-stop button on the base
control console
▪
The off/base/platform key switch.
Function Tests
Do the function tests as specified in
Section 4.3
.
When you do the function tests, make sure that the
green light on the keypad is ON. This light confirms
that the access control unit is in operation. Do the
function tests for these power connections in the set
time:
▪
The main power disconnect switch
▪
The emergency-stop button on the base control
console
▪
The off/base/platform key switch.
F
A
M
IL
IA
R
IZ
A
T
IO
N
Summary of Contents for SJ40 T+
Page 4: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 4 Notes ...
Page 10: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 10 Notes ...
Page 14: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 14 Notes ...
Page 22: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 22 Notes ...
Page 40: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 40 Notes ...
Page 64: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 64 Notes ...
Page 72: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 72 Notes ...
Page 83: ...SJ40 T SJ45 T SJ61 T SJ66 T 213201ACA 83 Section 7 Technical Diagrams and Specifications ...
Page 126: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 126 Notes ...
Page 128: ...213201ACA SJ40 T SJ45 T SJ61 T SJ66 T 128 Notes ...
Page 129: ...Cancer and Reproductive Harm https www p65warnings ca gov WARNING ...
Page 130: ...www skyjack com ...