158
SJ3220, SJ3226, SJ4720, SJ4726, SJ4732
223198ABA
Section 5 – Procedures
Skycoded Module
Menu
Selection
Sub-Menu
Description
SETUPS
M
A
C
H
IN
E
D
E
F
A
U
LT
S
See
5.4-5 Initial Set-up and Change Defaults Procedure
MODEL
Factory set to configure machine type; confirm that the correct customer code is displayed. Determines the
initial default settings of all ADJUSTMENTS; Set to change to the correct model code for the machine.
CURVE
Selects the proper preprogrammed load/height curve.
BATTERY
Selects the type of battery installed in machine.
VEHICLE
Selects the type of vehicle.
T
IL
T
S
E
T
U
P
S
See
5.4-7 Calibrate Level Procedure
CALIBRATE
LEVEL
Calibrates Control Module CM1 tilt to zero degrees X and Y.
TILT
SHUTDOWN
Determines if Control Module CM1 will prevent functions when machine is tilted:
NEVER – no functions prevented
LIFT&DRIVE – lifting and driving prevented (lowering still allowed)
LIFT – lifting prevented (lowering and driving still allowed)
DRIVE – driving prevented (lifting and lowering still allowed)
ELEV. TILT
SHUTDOWN
Determines if Control Module CM1 will prevent functions when machine is both tilted and elevated.
H
E
IG
H
T
S
E
T
U
P
S
ELEVATION@
Determines the “elevation” point – the platform height at which the machine is considered to be elevated.
CALIBRATE
HEIGHT
Calibrates platform height from 0% to 100%.
MIN LIFT
Determines the minimum time between each static measurement during load calibration.
SAMPLES@
Determines the time between samples during dynamic lifting load calibration.
TILT
CORRECTION
Configures how to correct machine tilt so that Control Module CM1 height measurement is correct.
SLOWDOWN
Determines whether to reduce lifting speed as platform height approaches MAX LIFT setting or not to make
sure there is no overshoot.
RED KNOB
Determines if machine was built with the “red knob” manual override in the Holding Valves for emergency
lowering.
ANTI
OVERRISE
Determines if the machine has optional KC Anti Overrising switches. 1=disable, 2=enable.
LO
A
D
S
E
T
U
P
S
See
5.4-8 Calibrate Load Procedure
CALIBRATE LOAD
Calibrates platform load estimation from 0% to 100% height, at rated load and empty, as measured by the lift
cylinder pressure sensor.
RESET
OVERRIDE
Determines if the count for Override function can be reset to zero.
FAULTY LOAD
Determines whether to prevent movement if load estimate is implausibly low (i.e. damaged pressure sensor).
DYNAMIC SCALE
Determines sensitivity to stop at OVERLOAD @HEIGHT, if platform load estimate is close to trip point.
FINETUNEup
Determines the percentage of fine tuning calculated during Calibration for UP movement.
FINETUNEdown
Determines the percentage of fine tuning calculated during Calibration for DOWN movement.
OL COUNT
HIDE or SHOW the count for Overload triggers made.(CE models only).
OL SWITCH
HYST
Determines the version of Overload switches (CE model only).
IN
T
E
R
LO
C
K
S
TRIGGERonly
Determines whether or not to trigger an interlock when the trigger is closed with no other function select and
after what delay to do it in.
TRIGGERwait
Determines whether or not to trigger an interlock when a function is selected without the trigger being closed
and after what delay to do it in.
Skycoded Control Module Menu Table (Continued)
Items highlighted in grey requires access level 2.
Summary of Contents for SJ 3220
Page 4: ...4 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Page 44: ...44 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Page 74: ...74 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Page 93: ...93 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Page 175: ...175 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Page 176: ......
Page 177: ...www skyjack com...