141
SJ3220, SJ3226, SJ4720, SJ4726, SJ4732
223198ABA
Base
Section 5 – Procedures
E-0-3-2
CAN Heartbeat Lost
▪
An error was detected with the CAN heartbeat
communications with a registered node being guarded.
▪
Check the networked CANbus device(s) for correct
functioning.
▪
This alarm does not display or get logged on the
charger but does appear on the CAN bus via an
emergency message.
E-0-3-6
Battery temperature sensor is missing or
shorted
▪
Check sensor connections.
▪
The charger behavior when this fault occurs can be
configured. OEMs may contact Delta-Q Technologies for
more information.
▪
This error automatically clears once the condition has
been corrected.
E-0-3-8
Fan will not turn
(Fan-equipped models only)
▪
Check fan connections.
▪
Check to make sure the fan turns freely and is not
obstructed.
▪
This error automatically clears once the condition has
been corrected.
E-0-4-0
Fan voltage pulled low
(Fan-equipped models only)
▪
Check to make sure the fan turns freely.
E-0-4-5
Battery disconnected
▪
Battery disconnected
▪
Reconnect the battery or check the wiring
E-0-4-6
Invalid PDO Length
▪
Check to make sure all PDOs are valid length.
▪
This error automatically clears once the condition has
been corrected
E-0-4-7
Platform overvoltage alarm
▪
A battery or some other source has been connected to
the charger that exceeds the hardware’s design limits.
Summary of Contents for SJ 3220
Page 4: ...4 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Page 44: ...44 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Page 74: ...74 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Page 93: ...93 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Page 175: ...175 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Page 176: ......
Page 177: ...www skyjack com...