SKYJACK, Page 87
SJRT Compact Series
Engine Powered
4.1-32. All Outriggers Inoperative (Auto Level Only)
B: Led Power Indicator Light at Outrigger Control Module (OCM1) Flashing
Flash Code
Probable Cause
Remedy
1/1
1.
Outriggers are all up and machine is
tilted.
1.
Level the machine.
1/2
1.
Machine is elevated.
2. Loose or broken wire # 35.
1.
Lower the scissor stack below high speed limit switch.
2.
Check for input voltage on wire #35 at pin P2-10 of the outrigger
control module (OCM1). Replace if defective.
2/2
1.
At least one outrigger is not fully
retracted.
2.
Defective outrigger rod limit switch
(LS61, LS62, LS63, LS64) or wiring.
3.
Defective diode (D36) on outrigger
board.
1.
Fully retract all outriggers.
2.
Replace defective or damaged switch(es) or wiring.
3.
Check for continuity. Replace if defective.
2/1
1.
Outriggers are all down and the machine
is not fully level.
1.
Move machine to less sloped terrain if it will not lift.
5/5
1.
Power on wire #70 or #79 at power on.
2.
Power on wire #70 or #79 when
manually operating outriggers.
1.
Check for power on wire #70 or #79 at pin P2-5 or P2-6 of the
outrigger control module. Replace defective component.
2.
Check for power on wire #70 or #79 while manually operating an
outrigger.
5/2
1.
Low or no voltage on wire #35c.
2.
Loose or broken wire on #35c.
1.
Check battery and charging system to ensure minimum 9 volts.
2.
Check for input voltage on wire #35c at pin P4-9 of outrigger
control module (OCM1).
7/1
1.
Excessive vibration.
2.
Defective outrigger control module.
1.
Outrigger control module cannot read tilt sensor.
2.
Replace.
6/6
1.
Outriggers are being manually
controlled.
1.
Indicates function activated. No repair necessary.
7/8
1.
Error occured while self diagnosing the
hardware fail safe.
1.
Turn off power to reset the outrigger control module. Turn power
back on and see if the code has cleared. If problem persists,
replace outrigger control module.
5/1
1.
Low input voltage to outrigger control
module.
1.
Check for minimum 9 volts between wire #02 at pin P2-11 and wire
#10A at pin P2-12 at outrigger control module.
7/7
1.
Startup error occurred while self
diagnosing.
1.
Turn off power to reset the outrigger control module. Turn power
back on and see if the code has cleared. If problem persists,
replace outrigger control module.
7/5
1.
Internal failure of OCM1.
1.
Turn off power to reset the outrigger control module. Turn power
back on and see if the code has cleared. If problem persists,
replace outrigger control module.
7/2
1.
Internal failure of OCM1.
1.
Turn off power to reset the outrigger control module. Turn power
back on and see if the code has cleared. If problem persists,
replace outrigger control module.
8/1
1.
Internal failure of OCM1.
1.
Turn off power to reset the outrigger control module. Turn power
back on and see if the code has cleared. If problem persists,
replace outrigger control module.
8/2
1.
Internal failure of OCM1.
1.
Turn off power to reset the outrigger control module. Turn power
back on and see if the code has cleared. If problem persists,
replace outrigger control module.
8/3
1.
Internal failure of OCM1.
1.
Turn off power to reset the outrigger control module. Turn power
back on and see if the code has cleared. If problem persists,
replace outrigger control module.
8/4
1.
Internal failure of OCM1.
1.
Turn off power to reset the outrigger control module. Turn power
back on and see if the code has cleared. If problem persists,
replace outrigger control module.
8/5
1.
Internal failure of OCM1.
1.
Turn off power to reset the outrigger control module. Turn power
back on and see if the code has cleared. If problem persists,
replace outrigger control module.
7/6
1.
Internal failure of OCM1.
1.
Turn off power to reset the outrigger control module. Turn power
back on and see if the code has cleared. If problem persists,
replace outrigger control module.
60416AB
Go
to
Discount-Equipment.com
to
order
your
parts