SKYJACK, Page 109
SJRT Compact Series
Engine Powered
Table 5-5 Auto-Leveling Outrigger Error Code Breakdown
These are internal faults. If the fault persists after the power has been reset, the outrigger control module
may need to be replaced.
RELEASE OUTRIGGER DEMAND!
5/5
Check inputs on P2 pins 5 & 6 - the “auto-level” or “auto-retract” input is active at power-on or
when it is not allowed to carry out the function.
OUTRIGGERS CANNOT BE MOVED!
1/2
Check input on P2 pin 10 – “auto-level” or “auto-retract” has been requested but the platform is
elevated.
NOT FULLY LEVEL
2/1
The outrigger legs are all down (touching the ground) but the platform is not fully level.
OUTRIGGERS NOT HOME
2/2
The outrigger legs are not all down (touching the ground) and also are not all home (fully
retracted).
B+ SUPPLY TOO LOW
5/1
CHECK OUTRIGGER SUPPLY (P4-9)
5/2
Check that the battery voltage is not too low.
VEHICLE TILTED
1/1
These is not a true fault – move the vehicle to level ground!
TESTING HWFS
7/8
STARTUP!
7/7
These are not true faults unless they do not clear – the start-up tests should only occur for a
short time.
OUTRIGGERS MANUALLY CONTROLLED!
6/6
This is not a true fault – the outriggers are being manually operated (one or more outrigger legs
on P4 pins 1-8 is high, when the outrigger control module is not active.
CANNOT LEVEL (BAD TILT SENSOR)
7/1
FAULT: BAD TILT SENSOR
7/1
FAULT: BAD HWFS
7/2
FAULT: BAD SLAVE MICRO
7/5
FAULT: HWFS STALLED!
7/6
FAULT: P2-5 FAULTY
8/1
FAULT: P2-6 FAULTY
8/2
FAULT: P2-8 STUCK ON
8/3
FAULT: P2-8 ALWAYS ON
8/4
FAULT: P2-8 ALWAYS OFF
8/5