9. Loose or broken wire #63 from outrigger board to outrigger limit switch (LS62).
- Check continuity. Replace if defective.
10. Defective Limit Switch (LS62).
- Check switch. Replace if defective.
11. Loose or broken wire #62 from outrigger limit switch (LS62) to outrigger board.
- Check continuity. Replace if defective.
12. Loose or broken wire #62 from outrigger board to outrigger limit switch (LS61).
- Check continuity. Replace if defective.
13. Defective outrigger limit switch (LS61).
- Check switch. Replace if defective.
14. Loose or broken wire #61 from outrigger limit switch (LS61) to outrigger board .
- Check continuity. Replace if defective.
15. Open diode (D36) on outrigger board.
- Check diode. Replace if defective.
4.1-26. Platform Will Not Lift From Platform or Base Controls With Outriggers
Extended
1. Outriggers not extended enough.
- Extend outriggers to take weight off tires (refer to operator section).
2. Loose or broken wire #10A from base terminal block (TB1) to pin #15 on connector (CN22) at the
outrigger board.
- Check continuity. Replace if defective.
3. Loose or broken wire #10A from outrigger board to outrigger limit switch (LS68).
- Check continuity. Replace if defective.
4. Defective outrigger limit switch (LS68).
- Check switch. Replace if defective.
5. Loose or broken wire #68A from outrigger limit switch (LS68) to outrigger board.
- Check continuity. Replace if defective.
6. Loose or broken wire #10A from outrigger board to outrigger limit switch (LS67).
- Check continuity. Replace if defective.
7. Defective outrigger limit switch (LS67).
- Check switch. Replace if defective.
8. Loose or broken wire #67A from outrigger limit switch (LS67) to outrigger board.
- Check continuity. Replace if defective.
9. Loose or broken wire #10A from outrigger board to outrigger limit switch (LS66).
- Check continuity. Replace if defective.
10. Defective outrigger limit switch (LS66).
- Check switch. Replace if defective.
11. Loose or broken wire #66A from outrigger limit switch (LS66) to outrigger board.
- Check continuity. Replace if defective.
12. Loose or broken wire #10A from outrigger board to outrigger limit switch (LS65).
- Check continuity. Replace if defective.
13. Defective outrigger limit switch (LS65).
- Check switch. Replace if defective.
14. Loose or broken wire #65A from outrigger limit switch (LS65) to outrigger board.
- Check continuity. Replace if defective.
15. Check for power on wire #65 at outrigger control module at pin P2-8.
- If no voltage present, proceed to Outrigger Control Module Troubleshooting.