Section 2 - List of Tables
Table 2.4b Floor Loading Pressure - CE
kg
lb.
kg
lb.
kPa
psi
kg/m
2
psf
min*
2903
6400
1161
2560
1085
157.4
1007
206
max*
3960
8730
1584
3492
1209
175.41
1373
281
min*
3475
7661
1390
3064
1142
165.59
1205
247
max*
4189
9235
1635
3605
1250
181.36
1452
297
60442AE-CE
*
**
NOTE:
MODEL
6832
Total Machine Load
6826
Total Machine Weight
Wheel
OUP**
min
- Total machine weight with no options
max
- Machine all o full capacity
The
LCP
or
OUP
that an individual surface can withstand varies from structure to structure and is generally determined by the engineer or architect
for that particular structure.
LCP**
LCP – Locally Concentrated Pressure
is a measure of how hard the machine presses on the areas in direct contact with the floor. The floor covering
(tile, carpet, etc.) must be able to withstand more than the indicated values above.
OUP – Overall Uniform Pressure
is a measure of the average load the machine imparts on the whole surface directly underneath it. The structure of
the operating surface (beams, etc.) must be able to withstand more than the indicated values above.