22
Programming
NOTE: When 9999 is entered in Celsius mode, it will show as 5538 during the REVIEW of the
program.
Prepare Venting and Start
Before starting the program, it is always a good idea to press REVIEW and make sure the data was
entered correctly. If you find an error, simply press RAMP/HOLD and then continue to press ENTER
until you find the error and are able to correct it. If there is a Delay entered, when you press START
the kiln will begin counting down from the input time. Remember to turn on your vent (or prop your
lid) before pressing START.
Advanced Features
16-S
While it is highly unlikely you will ever need a program with more than 32 segments, this feature
allows you to create a program with up to 64 segments. When the 16-S feature is toggled ON,
the controller links RAMP/HOLD programs #5 and #6. Now, when you run program # 5, it will
automatically run program #6 to continue the firing after program #5 has completed. Due to
requirements of the software, the first segment of Program #6 must be increasing in temperature.
Here is how to use this feature:
Step 1 - Input a 1 to 32 segment RAMP/HOLD Program in PROG #5.
Step 2 - Input a 1 to 32 segment RAMP/HOLD Program in PROG #6.
Step 3 - Press RAMP/HOLD, press 5. Press ENTER. Press STOP.
Step 4 - Press MENU. The Display will show SET. Press ENTER. The Display will show PRHT. Press
MENU until the display shows 16-S then press ENTER. The display will show OFF. Toggle to ON by
pressing the 1 key, then press ENTER .
Step 5 - Press REVIEW. Press START.
IMPORTANT. Program #5 must be cued prior to toggling the feature ON. Once both programs have
run, the controller automatically toggles OFF the 16-S feature.
Skip Step
Skip any segment in a Ramp/Hold Program during a firing by pressing VIEW quickly followed by
pressing ENTER. If done quick enough you will see SKIP in the display. Immediatly press ENTER
again.
Cone Correlation
The 700 Board allows you to utilize the cone correlation benefits of CONE FIRE Mode coupled with
the flexibility of RAMP/HOLD MODE
.
To use Cone Correlation to calculate your final temperature
during a RAMP/HOLD program, press CONE TABLE instead of entering a temperature for your final
heating segment. Input the Cone Value you would like to correlate and
press
ENTER.
Running a Stored Ramp Hold Program
Step 1
Press RAMP/HOLD.
Step 2
Input desired stored program number.
Step 3
Press
ENTER.
Step 4
Press
STOP.
Step 5
Press
REVIEW.
Step 6
Press
START.