41
Replacing the Thermocouple
●
Remove the screws that secure the red control box to the kiln.
●
Swing the box open.
●
The thermocouple has a yellow, insulated lead wire attached to the terminal
strip with slide on connectors and marked with positive (+) and negative (-).
Note: The negative (-) wire is red, not black!. Slide the connectors off the
terminal strip.
●
Remove the two screws that hold the thermocouple terminal block onto the
heat shield.
●
Gently pull the thermocouple assembly out of the brick.
●
Loosen the two screws which hold the thermocouple element in place as
shown in the picture at right and remove it from the thermocouple block.
●
Insert the new thermocouple element in place and tighten the screws.
●
Reattach the terminal block onto the heat shield with the two screws.
●
Reconnect the thermocouple lead wire to the terminal strip, matching the
positive and negative markings.
●
Close the box
KilnMaster Controller Circuitry
The KilnMaster controller components are solid state and cannot be
repaired in the field. If repairs are necessary, call the factory at 503-774-
6000 to arrange repairs.
Do not send items without proper authorization.
Repairs