11
SKOPE TME Series
Servicing
User Manual
Troubleshooting
For problems with the chiller and refrigeration unit, use the following table.
Problem
Possible Cause
Suggestions
• Chiller not operating • Loss of power
supply
• Check mains power supply.
• Interior light not on
• Failed LED tube
• Replace LED tube (see
• Blown chiller fuse
• Contact an authorised
service agent to replace it.
• Power consumption
is higher than
expected
• Unit operating too
hot
• Clean the condenser coil
• Ensure the chiller has good
ventilation around the
refrigeration unit (see
page 5).
• Ensure the chiller is in a
cool spot.
• chiller doors are
opened excessively
• Ensure doors are closed
more often.
• Product is too warm
• Restricted airflow to
chiller
• Ensure product is not
blocking airflow slots.
• Ensure there is space
around individual product
pieces.
• Warm chiller
temperatures
• Compressor
operating for long
periods (more than 1
hour)
• Blocked condenser
• Clean the condenser coil
• Poor ventilation
around refrigeration
unit
• Ensure the chiller has good
ventilation around the
refrigeration unit (see
page 5).