27
SK650-2
SKOPE Gen2: Single Door Chiller
Door removal
For ease of servicing, and reversing hinging, the door can be
removed from the cabinet. To remove the door:
1. Disconnect the cabinet from the mains power supply.
2. Slowly release tension on the door capstan, by turning the
capstan with a Ø2.5mm steel rod, and removing the split pin
from the bottom hinge bracket.
3. Unscrew the bottom hinge. Important: ensure the weight of the
door is fully supported, before removing the bottom hinge.
4. The door and hinge can now be removed from the cabinet.
To refit the door:
1. Lift the door onto the top hinge pin. The weight of the door will
need supported, until the bottom hinge is fitted.
2. Locate bottom hinge onto door capstan, and attach to cabinet.
3. Check alignment with other doors, and adjust as necessary.
4. Re-tension the door (see ‘Door tension’ on page 25).
Hinge reversal
The glass door can be hinged on either the left or right hand side. To
reverse the door hinging opposite hand top and bottom hinges are
required.
1. Remove the door (see ‘Door removal’ above).
2. Remove the existing top and bottom hinges and replace with
the opposite hand hinges (see page 54 for part numbers).
3. Remove the torsion bar assembly from the door.
4. Refit torsion bar assembly into the opposite end of the door.
5. Refit top door bush.
6. Refit the door to the cabinet (see ‘Door removal’, above).
7. Re-tension the door (see ‘Door tension’ on page 25).
SERVICE INSTRUCTIONS
4
Summary of Contents for SK650-2
Page 2: ......
Page 47: ...47 SK650 2 SKOPE Gen2 Single Door Chiller Notes SERVICE INSTRUCTIONS 4 ...
Page 48: ...48 SK650 2 SKOPE Gen2 Single Door Chiller 5 1 Model SK650 2 Type V60BA WIRING DIAGRAMS 5 ...
Page 50: ...50 SK650 2 SKOPE Gen2 Single Door Chiller 5 2 Model SK650 2 Type V60BB WIRING DIAGRAM 5 ...