SKOPE Gen2: Single Door Chiller
3.3 Programming Controller
The controller keypad must always be locked, to prevent unauthor-
ised modification.
To unlock the keypad (to modify parameters)
Press both the
UP
and
DOWN
keys until ‘Pon’
is displayed.
How to lock the keypad
1. Press and hold both the
UP
and
DOWN
keys for more than 3 seconds.
2. The ‘PoF’ message will be displayed and
the keypad will be locked. At this point it will be possible only to
see the Set Point or maximum or minimum temperature stored.
3. If a key is pressed for more than 3 seconds, the ‘PoF’ message
will be displayed.
To display the Set Point
Press, and immediately release the
SET
key. The
display will show the Set Point value, and the Set Point
LED will be highlighted.
To change the Set Point
1. Push and hold the
SET
key for
more than 2 seconds.
2. The value of the Set Point will be
displayed, and the LED will start blinking.
3. To change the Set value, push the
UP
or
DOWN
keys.
4. To memorise the new Set Point value, push the
SET
key again
or wait 15 seconds.
ELECTRONIC CONTROLLER
3