Page 14 of 68
Page 15 of 68
SKIPPER
Electronics AS
Edition:
2021.11.04
SKIPPER
Electronics AS
Edition:
2021.11.04
ESN200 Operation and Installation Manual
ESN200 Operation and Installation Manual
Chapter: CONFIG software setup
Chapter: CONFIG software setup
Max range (set automatically for part number,
adjustable for ‘other’)
Max Power: This system is up to 1kW Peak
power, and this can be limited if required
Sensor frequency low: if the sensor is a dual fre
-
quency then this is s the low frequency or main
frequency if not
(available frequencies are 24, 30, 33, 38, 50,
100, 200 kHz)
Sensor frequency high: If dual frequency this is
the high frequency
Switch to low Freq below Range: At this depth
a dual frequency transducer will switch between
low/high
Position (FWD,AFT,PORT,STRB)
Part number, or other
Approved part numbers, are
ETN050 (50kHz)
ETN200/ETS200 (200kHz)
ETN200S/ETS200 (200kHz for valve)
ETS50200 (combined 50/200kHz)
ETN38 (38 kHz)
Draft of this sensor, can be changed on main
screens
Offset. Distance from transducer to keel
Current Frequency 200 or 50kHz. – The current
frequency in use on this transducer. (selectable
on dual frequency transducers)
Approved Primary: Any of the above transducers
can be primary, if a non approved transducer is
used as the second transducer, this must not be
primary
Settings available only in the case Part
number is ‘other’:
Main setup
Echosounder parameters are set by default, but can be adjusted in the “ES Setup”, “Main Setup”
Auto functions will take control of range, gain (and frequency for
ETS50200)
Vessel image: Change the design of the vessel in the menus
Speed of sound can be changed with an option or with a temper
-
ature input. User can only define the sound speed with an option
code.
Depth units (also available on screen). m (meters) ft(feets) fm
(fathoms)
Speed units: kn, m/s, Mi/h
Power Ch1:Power output 0-100% Normally controlled by Auto
when Auto function ON
Gain Channel 1: Receiver Gain 1-12. Normally controlled by Auto
when Auto function ON
Power Ch2: Power output 0-100% Normally controlled by Auto
when Auto function ON
Gain Ch2: Receiver Gain 1-12. Normally controlled by Auto when
Auto function ON
Pinging multiplexed: YES/NO.
No: The two transducers will ping simultaneously.
YES: Each transducer will ping every second time. This to avoid
interference if having two transducers with the same frequency
Save setup: Save setup to internal memory
Restore setup: Restore a saved setup
Reset will reset the settings to default