ESN200 Operation and Installation Manual
ESN200 Operation and Installation Manual
Chapter: Mechanical installation
Chapter: CONFIG software setup
CONFIG software setup
The ES system setup is accessed by pressing “CONFIG” button in left upper corner.
Available Setup screens:
• Runtime screen setup
•
Alert setup
• Diagnostics
• ES Setup
•
Communication setup (NMEA)
• 24 hours history
•
AUX Setup
•
JB70 Setup
•
Logging Setup
• Display setup
• Print Setup
Additionally the “STANDBY” button is
available to put system in standby for
a period not in use. Will switch off the
display and pinging.
Transducer settings and output settings are password
protected for changes.
The password for all units is ‘service’. The password will
be remembered for 1 hour, or until reboot of the system.
NMEA 3 IN+ NMEA 3 IN - +24 V
NMEA 3 OUT+ NMEA 3 OUT - 0 V
04
02 06
03
01
05
R2
R1
CU NMEA 2 IN
+ -
B+ A -
B+ A -
B+ A -
B+ A -
CU NMEA 1 IN
CU NMEA 1 OUT
CU NMEA 3 OUT
CU NMEA 3 IN
Power input (24VDC)
GRD STUD
Do not ground screen here
Transducer 1
Transducer 2
Coded plugs
LAN
CN 1
1
11
12
2
LAN
CN 1
ESN200-SB
TO INS. IEC61162-45O
*
ALARM
GPS / BAM
(Not in use)
+ -
+ -
+ -
+ -
+ -
+ -
+ -
+ -
+ -
NMEA 2 OUT
NMEA 2 OUT
NMEA 2 IN
NMEA 1 OUT
NMEA 1 OUT
8
2
7
1
5 6
3 4
07
03
10
06
02
05 09
R1
R2
12
08
01
04
11
0 V
24 V
PULSE LEVEL OUTPUT
ALARM +
0 V
+24 V
N
L G
+24 V 0 V
0 V
+24 V
N
G
L
5 -24V
5 -24V
SWITCH
BAM / VDR INS/ECDIS RADAR
OR BETTER
RESET -
CAT 5e
6
1 2 3
11
7
5
4
12
10
8
4 6
3
7
1
5
9
8
2
7 8
4 5 6
3
1 2
2
1
2
1
3
2
NMEA 1 IN
12
10
08
06
04
02
11
09
07
05
03
DC
AC
AUX 0 V
AUX IN 1
AUX OUT 2
AUX OUT 1
AUX 5 V
R2
R1
1
01
*
AUX OUTPUT ADD RESISTOR TO GIVE MAX 100 mA 24 V = 220 Ohm 5 V = 50 Ohm
NMEA - = A
NMEA + = B
COM.
NC
NO
J3
J2
J1
J1
J2
2
6
1
5
2
11
12
1
NOT USED
DC (24V) Power for DL2
AC (115V-230V) Power for DL2
JB70E2-SA
12
2
11
1
POWER
LAN
AUX OUT 3 Relay
J3
PIN 1
GND
1 2 3
3
2
1
3
2
1
Transducer 1
Transducer 2
White Gnd Black
Black
Gnd
White
Transducer 2
Transducer 1
Coded plugs
**
**
NC (normally closed) is in contact with COM when power OFF Relay default set as: Power Alerm Failure. Will engage with AC or DC power ON.
Length of
cable
Cable Area
0-100
1,5mm²
100-300
2,5mm²
>300
E
F
C
1
2
3
4
B
A
3
2
1
5
C
D
4
6
7
8
A
B
Electronics AS
D
E
ISO2768m
Gen. tolerance
Eur. projection
N/A
Material
2021.03.22
Checked by
2018.08.28 ST Endret til JB70E2-SA
CN
Drwg. no.
Name
PC 2018.11.15
Edition date
Sheet
01
Revision
CD-2043
Scale
Wiring diagram for ESN200
1 of 1
Designed by - date
ST 2018.06.12
Approved by - date
2018.11.15 ST Endret til ESN200-SB og lagt til/endret diverse Connectorer
Rev. 01. 2021.02.15 ST Endret på jording på LAN
Explain AUC OUT 3 better. ST 2021.03.22
First Page
Prev Page
Next Page
Last Page
First Page
Last Page
Prev Page
Next Page