ESN200 Operation and Installation Manual
ESN200 Operation and Installation Manual
Chapter: CONFIG software setup
Chapter: CONFIG software setup
Power failure alarm:
If the power to the unit fails, this state must be indicated to the bridge in an audible form. If no
other method is available, a beeper can be connected to the AUX out (See section AUX setup),
and on failure the beeper will sound. In the case of just the JB70 Electronic unit failing the Display
will give an alert.
Alert Values
Alert
Range
Default
Shallow water (Keel)
1-99 m
10m
Deep Water (Keel)
2-5000m
Can not be less than shallow water
alarm
OFF
Settings
Setting
Selection
Default
Description
Alert group
System, CAM1, CAM2,
BAM1, BAM2
System
The LWE group for alert messages
to be sent on
BAM/CAM SFI
XXYYYY
(X is letter Y is number)
CA1235
The Identity of the centralised
alarm system
Alert type
ALF, ALR
ALF
The type of alert messages to be
sent, ALF or ALR with or without
acknowledge of shallow water
Escalation time
1m, 2,3,4,5 m
2 min
If escalation is selected on a warn
-
ing, this becomes an alarm after
this time.
The system is compliant with 2018 version of IEC62923.
The alerts setup page will allow the alerts to be setup by category, an alert ID number being
assigned to the alert, according to the standard. These alerts can be disabled if required.
It is possible for multiple alerts to show, and these will be shown as symbol on the runtime
screen, pressing these will give details and pressing ‘?‘ on the alert dropdown, will take the user
to the diagnostic screen where there may be more information about the cause.
Alerts will be logged in the 24h history and can be seen in the table view or on the history
screen using the mark feature.
The alerts will be sent out using the IEC61162-1/NMEA and IEC61162-450 LWE standard sen
-
tences. Aggregation is not in use for these sentences.
Responsibility transfer is available on the system failure warning. This means the alert on Serial
output will be present slightly before the alert shows on screen.