![Skipper ESN100 Operation And Installation Manual Download Page 46](http://html1.mh-extra.com/html/skipper/esn100/esn100_operation-and-installation-manual_1288612046.webp)
Page 46 of 56
SKIPPER
Electronics AS
Edition: 2021-09-16
ESN100 Operation and Installation Manual
Chapter: Diagnostics
Diagnostics
The ESN100 has a number of functions to allow the user to simulate, diagnose and optimise the
system.
The Diagnostics setup will help identify the problem.
Parameter
Description
Simulate depth
Make a depth of the desired value (Depth button) To test outputs and
alarms, alternatively have a moving depth , or run a simulation from
file.
Depth
The value to be sent, or the value the moving depth will move above
and below.
Test alarm
Send all known alarms to the output. (These can be acknowledged/
silenced/ changed as a normal alarm/alert)
Noise self test
Run this to check the Noise levels of the system
SNR Calibration
Run this calibration to tune the system once installed in the vessel
Show Noise results Show the results of the noise test (See below)
Noise self test will run a series of pings and measurement within the system to find the noise con
-
ditions. These can be inspected by pressing the show noise button