EMES60 can accommodate the second echosounder Sensor Unit,
which can be connected to the NMES channel 3. If dual transducer
installation is active, the baud rate of the NMEA channel 3 is
automatically set to 115000 – to communicate to the sensor.
Touch the vessel icon – to toggle between the Single and Double
Sensor Unit installations.
Normally one of the transducers is installed in front of the vessel (Fore)
and the secondary – Aft the ship.
If double transducer installation is selected, one of the
Pulse inputs must be configured as the Transducer selector,
ref 4.6.5. The level on this pulse input will control which
sensor unit is active. If the level is low, the Fore Sensor is
active. If the level is high – The Aft Sensor is active.
Ref 8.2.6 for connecting the control switch.
Reset to default settings
The default settings of the Interface Unit can be restored to
factory default values when necessary
NMEA output setup
NMEA 0183 messages can be output on three
serial ports; use the tick-boxes to select which
messages are sent out on which serial port.
Each serial port can output any number of the
available messages. See section 8.4 for a
description of the supported output NMEA 0183
messages.
Touch the frame with indicated baud rate
value – to change the baud rate. Select one
out of:
2400; 4800; 9600; 19200; 38400; 57600; 115200
The following inputs are available: