13
•
Mounting saw blade
2
! remove battery from tool
-
take hex key A from storage B
-
push spindle-lock button C and hold it while you
remove blade bolt D by turning hex key A
CLOCKWISE
(= in same direction as arrow printed on saw blade)
!
push spindle-lock button C only when tool is at a
standstill
-
release spindle-lock button C
-
remove flange E
!
make sure that clamping surfaces H of flanges are
perfectly clean and face the blade
-
open lower guard F with lever G and hold it while you
mount saw blade with saw teeth and arrow printed on
saw blade pointing in same direction as arrow on upper
guard
-
release lower guard F
-
mount flange E
-
push spindle-lock button C and hold it while you
tighten blade bolt with hex key 1/8 turn past finger tight
(ensures slippage of saw blade when it encounters
excessive resistance thus reducing motor overload and
saw kickback)
-
release spindle-lock button C
•
Adjusting cutting depth (0-41 mm)
8
-
for an optimal quality cut the saw blade should not
extend more than 3 mm below the workpiece
-
loosen knob J
-
raise/lower foot K until desired cutting depth is set on
scale using indicator L
-
tighten knob J
•
Adjusting cutting angle (0-50°)
9
-
loosen knob M
-
tilt tool until desired cutting angle is set on scale using
indicator N
-
tighten knob M
! when bevel cutting, cutting depth does not
correspond with value on cutting depth scale
•
90° Cutting angle check
9
-
adjust and tighten foot K to maximum cutting depth
8
-
adjust and tighten cutting angle to 0°
-
check for a 90° angle between the blade and bottom of
foot with a square
-
if adjustment is needed, loosen knob M and use
adjustment screw P as illustrated
•
Line-of-cut indicator Q
q
-
for guiding tool along desired line of cut marked on the
workpiece
-
for a straight 0° cut or a 45° bevel cut use the indicator
line concerned
! the wide part of the foot should rest on the
supported part of the workpiece
! cutting width is determined by width of blade teeth
and not by width of blade body
!
always make trial cuts first to verify actual line of
cut
•
Dust suction
w
For using vacuum cleaner
-
connect vacuum cleaner hose to vacuum cleaner
adapter R
! never let the vacuum cleaner hose interfere with
the lower guard or the cutting operation
•
After switching off your circular saw, never stop the
rotation of the saw blade by a lateral force applied
against it
BATTERIES
• The battery supplied is partially charged
(to ensure
full capacity of the battery, completely charge the battery
in the battery charger before using your power tool for the
first time)
• Only use the following batteries and chargers with
this tool
-
SKIL battery: BR1*21**** / BR1*27****
-
SKIL charger: CR1*21**** / CR1*27****
•
Do not use the battery when damaged; it should be
replaced
•
Do not disassemble the battery
•
Do not expose tool/battery to rain
•
Permitted ambient temperature (tool/charger/battery):
-
when charging 4...40°C
-
during operation –20...+50°C
-
during storage –20...+50°C
EXPLANATION OF SYMBOLS ON TOOL/BATTERY
3
Read the instruction manual before use
4
Batteries may explode when disposed of in fire, so do not
burn battery for any reason
5
Store tool/charger/battery in locations where temperature
will not exceed 50°C
6
Do not dispose of electric tools and batteries together
with household waste material
USE
•
Charging battery
! read the safety warnings and instructions
provided with the charger
•
Removing/installing the battery
2
•
Battery level indicator
7
-
press the battery level indicator button AC to show the
current battery level
7
a
! when the lowest level of the battery indicator
starts flashing after pressing button AC
7
b, the
battery is empty
!
when 2 levels of the battery indicator start flashing
after pressing button AC
7
c, the battery is not
within the allowable operating temperature range
•
LED-light V
e
LED-light automatically lights on when activating the on/
off switch
!
when LED-light starts flashing, the battery
protection is activated (see below)
•
Battery protection
The tool is suddenly being switched off or prevented from
being switched on, when
-
the load is too high
--> remove load and restart
-
the battery temperature is not within the allowable
operating temperature range of -20 to +50°C
--> 2
levels of the battery level indicator start flashing when
pressing button AC
7
c; wait until battery has returned
within the allowable operating temperature range
-
the battery is nearly empty (to protect against
deep discharge)
--> a low battery level or flashing low
battery level
7
b is shown by the battery level indicator
when pressing button AC; charge battery
!
do not continue to press the on/off switch after the
tool is switched off automatically; battery may be
damaged
Summary of Contents for 2550
Page 5: ...5 8 3 mm J 7 P 9 AC L N M 7 7 7 a b c ...
Page 6: ...6 Ø35 36mm w q NOT STANDARD INCLUDED AD Y T W R S Q ...
Page 7: ...7 e V r ...
Page 8: ...8 Z u t AA y F G Q ...
Page 9: ...9 i ACCESSORIES WWW SKIL COM ...
Page 186: ...186 WWW SKIL COM i ...
Page 187: ...187 Z u t AA y F G Q ...
Page 188: ...188 e V r ...
Page 189: ...189 ال رفوتي ًيسايق ا عم ةادألا Ø35 36mm w q AD Y T W R S Q ...