7.6.1 Shut down MAX1 and MAX3
1
Pull the power line plug of the control unit out of the power outlet.
2
Pull the low-voltage plug (Jack plug or DIN-8 plug) of the cable of
the device out of the connecting socket of control unit (
†
Refer to
paragraph below
).
Pull jack plug out of control unit
Proceed as follows to pull jack plug out of the connection outlet of
the control unit:
• Special tools required:
–
Special tool from the manufacturer (part no. 0125322)
1
Insert special tool (
1
) in the groove (
2
) of the jack plug.
2
Turn special key (
1
) counter-clockwise until the bayonet joint of
the jack plug is unlocked.
1
2
Fig. 53
3
Pull jack plug (
1
) out of the connection outlet (
2
) of the control
unit (arrow).
2
1
Fig. 54