background image

Fig. 6

3

13

8

14

23

16

4

12

20

2

5

17

15

8

16

Replace 9 V battery

Press 

TEST

 (

22

) (

† fig. 5,

 

pg. 6

) to 

disable pump activity.

Remove two socket head cap screws 
(

12

) (

† fig. 6

) in the indented part on 

rear lip of overrun controller (

8

) and two 

screws (

13

) on the rear side corners of 

back cover (

3

).

While ensuring all three interior wires 
remain connected, lift back cover (

3

) off 

rear portion of overrun controller (

8

).

Press and release power button (

16

) on 

rear of front portion of overrun 
controller (

8

).

Remove four phillips screws (

14

) on 

front of overrun controller (

8

) and lift 

front cover panel (

15

).

Pull the 9 V battery from void in lower 
right corner of the circuit board.

Disconnect old battery from snap 
connector.

Connect new 9 V battery to snap 
connector.

Insert battery back into void in lower 
right corner of circuit board.

10 

Press and release power button (

16

)

 

on 

rear of front portion of the overrun 
controller (

8

).

11 

Viewing front panel of overrun controller 
(

8

)

,

 confirm digital display (

17

)

 

lights up 

for 3 seconds.

 

The first row displays software ver-
sion operating the overrun controller.

 

The second row displays voltage 
coming from the battery.

12 

Attach front cover panel (

15

) to overrun 

controller (

8

)

 

by replacing phillips screws 

(

14

).

13 

Attach back cover (

3

) by re-inserting two 

socket head cap screws (

12

) into 

indented portion of front of overrun 
controller (

8

) .

14 

Install two screws (

13

) on rear side 

corners of back cover (

3

).

15 

To restart pump activity, press 

TEST

 

(

22

) (

† fig. 5,

 

pg. 6

).

8

Summary of Contents for Lincoln V340HH

Page 1: ...uide Read manual prior to installation or use of this product Keep manual nearby for future reference Failure to follow instructions and safety precautions may result in death or serious injury DANGER...

Page 2: ...r s recommendations regarding fluid compatibility and the use of protective clothing and equipment Failure to comply may result in personal injury and or damage to equipment Wear adequate personal pro...

Page 3: ...nuously monitored by a Programmable Control Board PCB for correct operating cycles If the pump cycles exceed PCB settings a solenoid is activated which utilizes compressed air to shutoff pump operatio...

Page 4: ...er back cover 3 remain connected Notice Save original rectangular plate 10 for future use Installation 1 Turn off pump 2 Remove four screws 9 and top plate 10 from module on back of pump fig 1 Fig 2 F...

Page 5: ...socket 26 5 Pry out DIN socket insert 33 from DIN socket housing 32 using a small flat head screwdriver 6 Referring to fig 4 thread wiring from PLC or other remote monitor through cap 27 washers 28 2...

Page 6: ...eck this or any error press B 21 Run mode Refer to table 3 for run mode options Once overrun controller is properly installed press A 20 fig 5 to start pump When pump is running without any errors gre...

Page 7: ...4 for overrun mode options Hold A 20 for 5 seconds to reset overrun error condition fig 5 pg 6 Sleep mode The overrun controller enters sleep mode when it does not receive any pressure switch signals...

Page 8: ...er of the circuit board 7 Disconnect old battery from snap connector 8 Connect new 9 V battery to snap connector 9 Insert battery back into void in lower right corner of circuit board 10 Press and rel...

Page 9: ...deactivate pump off Blue 250 mA 12 V DC Solenoid common Black 250 mA 12 V DC Solenoid activate pump on Grey 250 mA 12 V DC Pressure switch signal Orange 1 mA 5 V DC Pressure switch supply Red 10 mA 5...

Page 10: ...1 Pressure switch kit 286425 2 Mounting plate kit 286431 right side 286431 left side 3 PCB enclosure kit 286427 4 Solenoid valve kit 286428 5 Valve cap assembly kit 286429 6 End plug kit 286424 7 Seal...

Page 11: ...72 85782 and replacement injectors 85771 85781 Lincoln warrants the SL V Injector series to be free from defects in material and work manship for two 2 years following the date of purchase If an injec...

Page 12: ...equipment reliabil ity optimizing operational and energy efficiency and reducing total cost of ownership These competence areas include bearings and units seals lubrication systems mechatronics and a...

Reviews: