Operation

First use setup

!

Notice 

The upper row of display (

17)

 dis-

plays the current cycles/minute setting. 

The lower row of display (

17)

 displays 

the new cycles/minute setting. 

!

Notice 

Pump activity can also be restart-

ed by first pressing 

A (20) 

to illuminate 

display (

17

). Press 

A (20)

 again to re-

start pump (

† fig. 5

).

!

Notice 

Follow the one time procedure 

which is detailed below for first use set-
up only.  

Do not use this procedure after first 

use setup.

Fig. 5

Table 3

Run mode key options

Button

Action

Result

A

Press once

Upper row of display shows set cycles/minute 

Lower row of display shows new/adjusted cycles/minute

Press twice

Turns display off; Restarts pump if pump not operating

B

Press once

Error display (00, no error)

Press twice

Upper row of display shows software version 

Lower row of display shows battery percentage

TEST

Press once

Shut off the pump

Press twice

Restart the pump

14

15

8

17

18

19

20

21

22

•  To manually stop pump activity and 

overrun controller, press 

TEST

 (

22

).

•  To restart pump activity, press 

TEST

 (

22

).

•  If the battery life drops below 25%, red 

LED light (

18

) will blink. To check this or 

any error, press 

B

 (

21

).

Run mode

Refer to 

table 3

 for run mode options.

•  Once overrun controller is properly 

installed, press 

A

 (

20

) (

† fig. 5

)

 

to start 

pump.

•  When pump is running without any 

errors, green LED light (

19

) blinks 

continuously.

•  If no key is pressed for more than  

30 seconds after pump starts,  
overrun controller goes into standby 
mode and turns display (

17

) off to 

conserve battery life. Pump and overrun 
controller continue functioning while in 
standby mode.

•  To turn display (

17

) on while in standby 

mode, press 

A

 (

20

).

Holding 

TEST (22)

, press

 B (21) + A (20) 

+ B (21)

 within 5 seconds (

† fig. 5

). Do 

not release 

TEST (22).

   

Continuing to hold 

TEST (22), 

adjust cy-

cles/minute value by pressing 

A

 (

20

). Each 

key press will reduce the cycles/minute 
value by 5 units.

Release 

TEST (22) 

and hold 

B

 (

21

) until 

display (

17

) blinks. This indicates the cy-

cles/minute value has been stored. Unit 
then automatically initiates run mode.

Setting cycles per minute

Do the following to modify the cycles/minute 
setting:

Holding 

TEST (22)

, press

 B (21) + A (20) 

+ B (21)

 within 5 seconds (

† fig. 5

). Re-

lease 

TEST (22).

Adjust cycles/minute value by pressing 

A

 

(

20

). Each key press will reduce the cy-

cles/minute value by 5 units.

To store the cycles/minute setting, hold 

B

 

(

21

) until display (

17

) blinks. Unit then 

automatically returns to run mode.

6

Summary of Contents for Lincoln V340HH

Page 1: ...uide Read manual prior to installation or use of this product Keep manual nearby for future reference Failure to follow instructions and safety precautions may result in death or serious injury DANGER...

Page 2: ...r s recommendations regarding fluid compatibility and the use of protective clothing and equipment Failure to comply may result in personal injury and or damage to equipment Wear adequate personal pro...

Page 3: ...nuously monitored by a Programmable Control Board PCB for correct operating cycles If the pump cycles exceed PCB settings a solenoid is activated which utilizes compressed air to shutoff pump operatio...

Page 4: ...er back cover 3 remain connected Notice Save original rectangular plate 10 for future use Installation 1 Turn off pump 2 Remove four screws 9 and top plate 10 from module on back of pump fig 1 Fig 2 F...

Page 5: ...socket 26 5 Pry out DIN socket insert 33 from DIN socket housing 32 using a small flat head screwdriver 6 Referring to fig 4 thread wiring from PLC or other remote monitor through cap 27 washers 28 2...

Page 6: ...eck this or any error press B 21 Run mode Refer to table 3 for run mode options Once overrun controller is properly installed press A 20 fig 5 to start pump When pump is running without any errors gre...

Page 7: ...4 for overrun mode options Hold A 20 for 5 seconds to reset overrun error condition fig 5 pg 6 Sleep mode The overrun controller enters sleep mode when it does not receive any pressure switch signals...

Page 8: ...er of the circuit board 7 Disconnect old battery from snap connector 8 Connect new 9 V battery to snap connector 9 Insert battery back into void in lower right corner of circuit board 10 Press and rel...

Page 9: ...deactivate pump off Blue 250 mA 12 V DC Solenoid common Black 250 mA 12 V DC Solenoid activate pump on Grey 250 mA 12 V DC Pressure switch signal Orange 1 mA 5 V DC Pressure switch supply Red 10 mA 5...

Page 10: ...1 Pressure switch kit 286425 2 Mounting plate kit 286431 right side 286431 left side 3 PCB enclosure kit 286427 4 Solenoid valve kit 286428 5 Valve cap assembly kit 286429 6 End plug kit 286424 7 Seal...

Page 11: ...72 85782 and replacement injectors 85771 85781 Lincoln warrants the SL V Injector series to be free from defects in material and work manship for two 2 years following the date of purchase If an injec...

Page 12: ...equipment reliabil ity optimizing operational and energy efficiency and reducing total cost of ownership These competence areas include bearings and units seals lubrication systems mechatronics and a...

Reviews: