Owner/operator 

responsibility

It is the responsibility of the owner/operator 
to properly use and maintain this 
equipment.

The instructions and warnings contained 

in this manual shall be read and understood 
by the owner/operator prior to operating this 
equipment.

It is the owner/operator responsibility to 

maintain the legibility of all warning and  
instruction labels.

The owner/operator shall retain this 

manual for future reference to important 
warnings, operating and maintenance 
instructions.

Intended Use

Model V340HH electronic air shutoff  
assembly is designed to operate exclusively 
with Lincoln PMV pumps

The function of the electronic air shutoff 

assembly, also known as an overrun con-
troller, is to prevent pump damage, due to 
high runaway speeds (excessive number of 
pump cycles per minute), if lubrication drum 
or tank is emptied.

The overrun controller will shut off the 

pump, and signal an alarm if the pump  
exceeds its pre-set cycle rate.

Any other use not in accordance with  

instruction will result in loss of claims for 
warranty and liability.

System Overview

The electronic air shutoff assembly operates 
as a pump speed monitor and overrun 
controller for instances where pump speed 
exceeds preset levels due to low lubricant 
levels.

Pump cycles are continuously monitored 

by a Programmable Control Board (PCB) for 
correct operating cycles. If the pump cycles 
exceed PCB settings, a solenoid is activated 
which utilizes compressed air to shutoff 
pump operation.

Table 1

Specifications

Air pressure

40 to 150 psi 

(2.7 to 10.3 bar)

Operating temperature

–40 to +150° F 

(

40

 

to

 

5° C)

.

Power

9 V battery (included in packaging, not installed 

in assembly)

Minimum functional voltage

7.2 V

Destructive voltage

14 V

Active current, maximum

350 mA

Range of preset pump speeds:

Minimum

5 cycles/minute

Maximum

75 cycles/minute

Default

75 cycles/minute

Table 2

Controls and indicators

Power on/off switch

Manual switch

Digital Display

Two 2-digit alpha-numeric outputs

Red LED

Blinks to indicate error detected

Green LED

Blinks to indicate pump fuctioning normally

Button A

See manual description

Button B

See manual description

TEST

See manual description

Relay (DIN connector)

Two state relay (normal open/normal closed)

Description

The electronic air shutoff assembly monitors 
pump speed as the overrun controller 
assembly receives a discharge of 
compressed air from the pump with each 
pump cycle.

A processor detects air discharges via a 

pressure switch. If the CPM (Cycles Per Min-
ute) exceeds a preset number of cycles, a 
solenoid is activated which redirects the dis-
charged air, which in turn activates a mech-
anism which interrupts pump operation.

For specifications, refer to 

Table 1

.

For a listing of controls and indicators,  

refer to 

Table 2

.

3

Summary of Contents for Lincoln V340HH

Page 1: ...uide Read manual prior to installation or use of this product Keep manual nearby for future reference Failure to follow instructions and safety precautions may result in death or serious injury DANGER...

Page 2: ...r s recommendations regarding fluid compatibility and the use of protective clothing and equipment Failure to comply may result in personal injury and or damage to equipment Wear adequate personal pro...

Page 3: ...nuously monitored by a Programmable Control Board PCB for correct operating cycles If the pump cycles exceed PCB settings a solenoid is activated which utilizes compressed air to shutoff pump operatio...

Page 4: ...er back cover 3 remain connected Notice Save original rectangular plate 10 for future use Installation 1 Turn off pump 2 Remove four screws 9 and top plate 10 from module on back of pump fig 1 Fig 2 F...

Page 5: ...socket 26 5 Pry out DIN socket insert 33 from DIN socket housing 32 using a small flat head screwdriver 6 Referring to fig 4 thread wiring from PLC or other remote monitor through cap 27 washers 28 2...

Page 6: ...eck this or any error press B 21 Run mode Refer to table 3 for run mode options Once overrun controller is properly installed press A 20 fig 5 to start pump When pump is running without any errors gre...

Page 7: ...4 for overrun mode options Hold A 20 for 5 seconds to reset overrun error condition fig 5 pg 6 Sleep mode The overrun controller enters sleep mode when it does not receive any pressure switch signals...

Page 8: ...er of the circuit board 7 Disconnect old battery from snap connector 8 Connect new 9 V battery to snap connector 9 Insert battery back into void in lower right corner of circuit board 10 Press and rel...

Page 9: ...deactivate pump off Blue 250 mA 12 V DC Solenoid common Black 250 mA 12 V DC Solenoid activate pump on Grey 250 mA 12 V DC Pressure switch signal Orange 1 mA 5 V DC Pressure switch supply Red 10 mA 5...

Page 10: ...1 Pressure switch kit 286425 2 Mounting plate kit 286431 right side 286431 left side 3 PCB enclosure kit 286427 4 Solenoid valve kit 286428 5 Valve cap assembly kit 286429 6 End plug kit 286424 7 Seal...

Page 11: ...72 85782 and replacement injectors 85771 85781 Lincoln warrants the SL V Injector series to be free from defects in material and work manship for two 2 years following the date of purchase If an injec...

Page 12: ...equipment reliabil ity optimizing operational and energy efficiency and reducing total cost of ownership These competence areas include bearings and units seals lubrication systems mechatronics and a...

Reviews: