4. Installation instructions
The product described in the mounting instructions may only be ins-
talled, operated, maintained, and repaired by qualiied experts. Qua-
liied personnel are persons who have been trained, instructed, and
familiarized by the user of the end product into which the system is
installed. These persons are considered capable of such tasks due to
their education, training, and experience with valid standards, condi-
tions, accident prevention regulations in effect, and installation
conditions. They should be able to carry out the required tasks and to
recognize – and thus avoid – any dangers that might otherwise occur.
A deinition of what constitutes a qualiied person and who are
unqualiied persons are stipulated in DIN VDE 0105 and IEC 364.
Before installing/positioning the product, remove the packaging
material and any transportation safety devices such as sealing plugs.
Keep the packaging material until any and all problems have been
clariied.
WARNING!
All installation, setting, maintenance and repair works on the
lubrication system must be carried out only when the conveyor
is off duty. Working closed to a running conveyor chain may
cause operator's injuries and/or important material damages.
Country-speciic accident prevention regulations and the operating
and maintenance instructions for the operator must be observed
when carrying out all installation work on machines.
4.1 Positioning and installation
The GVP lubrication system must be protected from moisture and
vibrations but on the other hand mounted so that it is easily acces-
sible to ensure that all further installation work can be carried out
without dificulty. Ensure that there is suficient circulating air to
prevent the system from overheating. For information on the maxi-
mum admissible ambient temperature, see the technical data
section.
The lubrication system is directly installed above the conveyor
chain on an especially adapted rail
(† ig. 5)
.
C AUTION!
It is necessary to properly secure the GVP lubrication system on
its support to prevent any accidental system fall. A system fall
may damage it or cause material damage and can also injure the
operator or other people.
NOTE
For the product-speciic technical data on a speciic lubrication
system, see the relevant documentation. If you do not have
access to this documentation, you can request it directly from
SKF.
2 × M10-6H
2 × M10-6H
827
±2
20
45
(20)
20
55
80
20
80
70
130
70
130
220
Fig. 4
NOTE
The customer is in charge of the modiication of the conveyor rail
for installing the GVP lubrication system. The modiication must
be ins accordance with the dimensions on ig. 5.
The GVP system must be itted to the rail with the two langes
(† pos. 1 ig. 5)
. Every lange has two ixing holes for screws ISO
4762 M10 length 20 mm.
12