background image

INSTALLATION AND OPERATING INSTRUCTIONS 
System communications 

SKF Multilog On-line System IMx-Rail 
User Manual Supplement 
Revision B 

11 (29) 

 

 

2.2  System communications 

 
The communications setup or mode, determines how the device will communicate 
with the wider system. There are 2 main alternative arrangements that can be used 
with the IMx-Rail: 
 

 

Server initiated (@ptitude Observer initiated communication) 

 

Client-Server (the IMx-Rail is the initiator of the communication) 

 
These are alternatives for @ptitude Observer/IMx communication, illustrated 
diagrammatically i

Figure 2.

 

 
Whilst in general, the different network connection possibilities (

1.2.1

 t

1.2.2

) can be 

considered as alternatives, there are limitations on the permissible combinations of 
network connection method and communication mode: 
 

1.  Server initiated, requires a server installed on a local network (with RJ45 or 

Wi-Fi connection). 
 

2.  Mobile data connectivity is only supported in Client-Server mode (device 

initiated communications). 

 
The choice between using a mobile data connection or a LAN connection (RJ45 or 
Wi-Fi), is part of the IMx-Rail configuration. 

2.3  SKF Multilog On-line System IMx-Rail enclosure 

mounting 

 
When selecting a location for the device, inside the coach or externally on the coach 
chassis or bogie, make sure to consider the following aspects: 
 

 

Position it to minimise vibration and to keep clear of high voltage equipment. 

 

Avoid unnecessary exposure to radiant heat or strong magnetic fields. 

 

Choose a location convenient for cable routing, to and from the enclosure. 

 

With unobstructed access and clearance for opening the lid. 

 

Suitable for an enclosure of this size and weight. 

 

That will accommodate all the required fixing points. 

 
Refer section 

3.5

 and 

Figure 5

 for the enclosure dimensions and fixing centres. They 

allow the enclosure to be directly mounted, but if needed, an installation specific 
mounting bracket can utilise these fixings. 
 

 

Summary of Contents for 15V-090-00082-100

Page 1: ...em IMx Rail User Manual Supplement Part Number 15V 090 00082 100 Revision B September 2020 Read this manual carefully before using the product Failure to follow the instructions and safety precautions...

Page 2: ......

Page 3: ...echnical support tracking your proof of ownership and staying informed about upgrades and special offers Please visit our website for more details on these benefits General Product Information General...

Page 4: ...is already published You may search the vast knowledge base within the self service web portal for answers to commonly asked questions FAQ how to articles technical specs installation and user manuals...

Page 5: ...ommunications 11 2 3 SKF Multilog On line System IMx Rail enclosure mounting 11 2 4 Power requirements 12 2 5 On train cabling 13 2 5 1 Cable glanding 14 2 6 GPS module connection notes 15 2 6 1 GPS l...

Page 6: ...3 3 11 Data processing memory 21 3 3 12 Certifications 21 3 3 13 Quality control 21 3 4 Connector details for SKF Multilog IMx Rail 22 3 4 1 IMx Rail 22 3 4 2 IMx 16Plus top end cap 23 3 4 3 IMx 16Pl...

Page 7: ...installed in an outer protective enclosure Figure 1 SKF Multilog IMx Rail arrangement of main system components The outer enclosure has been selected to allow the system to be mounted in either an int...

Page 8: ...module provides a wireless mobile data connection LTE GSM It can work world wide and provides connectivity to ptitude Observer software Mobile data functionality requires an activated SIM card or eSIM...

Page 9: ...table isolated power at 24 V DC to the IMx 16Plus It protects it from any incoming voltage transients whilst at the same time preventing any disturbance to the train power bus system from the IMx Rail...

Page 10: ...Fi or RJ45 connectivity are alternative infrastructures to connect the IMx Rail to the wider cloud network and cannot be used simultaneously Before beginning an installation it is important to assess...

Page 11: ...k with RJ45 or Wi Fi connection 2 Mobile data connectivity is only supported in Client Server mode device initiated communications The choice between using a mobile data connection or a LAN connection...

Page 12: ...EC 61076 2 101 cable mounting connector is supplied with the IMx Rail and further quantities can be ordered under the following reference CMON 4143 Socket power supply connector for SKF Multilog IMx R...

Page 13: ...stems Make sure that the power is disconnected before the installation begins The system power supply must be provided with an appropriately positioned clearly labelled full pole isolator or switch th...

Page 14: ...mended When routing or arranging cabling within the IMx Rail enclosure avoid where possible routing the analogue sensor cabling directly over the DC DC power module 2 5 1 Cable glanding The glands use...

Page 15: ...ted to the user terminals provided refer Table 2 below and section 3 4 1 Note that the RS485A A B terminals must be used Table 2 GPS module connections to IMx 16Plus Wire colour Description IMx Rail t...

Page 16: ...ssociated sensors are virtually maintenance free though a yearly inspection of all installed equipment is advised Good practice is to use the IMx Manager app to generate and compare annual SAT Site Ac...

Page 17: ...uring data label confirms product and company information CE marking WEEE marking and RoHS compliance The QR code contains the product information shown alongside it The supply voltage for the device...

Page 18: ...PRODUCT SPECIFICATIONS EU Declaration of Conformity 18 29 SKF Multilog On line System IMx Rail User Manual Supplement Revision B 3 2 EU Declaration of Conformity...

Page 19: ...0 7 g Number of axes 3 mutually perpendicular 3 3 2 Power For information on Power over Ethernet refer IMx 16 16Plus user manual Input power connector An M12 A coded IEC 61076 2 101 cable mounting con...

Page 20: ...onverter for each channel Maximum sampling frequency 102 4 kHz though lower for event capture Frequency range from DC to 40 kHz For further information refer IMx 16 IMx 16Plus user manual 3 3 7 Digita...

Page 21: ...10 Storage capacity For further information refer IMx 16 IMx 16Plus user manual 3 3 11 Data processing memory For further information refer IMx 16 IMx 16Plus user manual 3 3 12 Certifications Calibrat...

Page 22: ...ystems Currently no firmware support GND Ground connection for use as required by RS485 and or CAN 485A A B RS485 2 wire A and B terminals Modbus RTU for GPS module A1 A16 Analogue inputs 1 to 16 Anal...

Page 23: ...ctor service interface Note that for ease of access a USB mini B to USB A receptacle cable is pre fitted LED Pwr Power green normal on Sys System red normal off Sw Switch push button rescue button ent...

Page 24: ...hree walls of the enclosure two long and one short are pre fitted with blind plugs refer Figure 6 Figure 7 and Figure 8 for the drilling pattern arrangement These 21 cable entries are supplied sealed...

Page 25: ...ng sensors etc Figure 7 IMx Rail enclosure pre drilling back long wall 3 positions 1 connector in red The back wall has three cable entries and the input power connector This wall of the enclosure is...

Page 26: ...ule CMON 4139 is connected to the IMx Rail via a 5 m integral cable and should be fitted externally to the enclosure in a location that allows satellite tracking An M12 cable gland is included The ove...

Page 27: ...ectrical waste and electrical equipment should be recycled as specified by the WEEE directive and not be placed in the general refuse Product should be sent to an approved recycling centre for safe re...

Page 28: ......

Page 29: ...APPENDIX A Limited Warranty SKF Multilog On line System IMx Rail User Manual Supplement Revision B 29 29 Appendix A Limited Warranty SKF Limited Warranty Download the latest version from skf com...