2.7 Commissioning and Maintenance
2.7.1 System commissioning and security
System commissioning and troubleshooting is supported by the SKF Multilog IMx
Manager, software. This is an SKF app for both Android and iOS devices and is
available from the relevant app store. The app provides features to manage and
configure the IMx system and to visualise measurement data:
Important additional information and guidance in respect of system commissioning
and security can be found in the SKF Multilog IMx-16/IMx-16Plus User Manual.
2.7.2 Hardware Maintenance
The IMx-Rail hardware, i.e. IMx-16Plus, power supply and its associated sensors,
are virtually maintenance free, though a yearly inspection of all installed equipment is
advised. Good practice is to use the IMx Manager app to generate and compare
annual SAT (Site Acceptance Test) reports.
The IMx-16Plus
device does not need to be opened for hardware maintenance or
inspection. Refer to the Troubleshooting section of the SKF Multilog IMx-16/IMx-
16Plus User Manual, for guidance on checks that can be made and where necessary
contact SKF TSG for advice.
Any repairs to an IMx-Rail device should only be carried by an SKF repair centre.
They can source all required replacement parts, including the
and antenna:
CMON 4140: 24V Power Supply for IMx-Rail (for CMON 4116-R-24)
CMON 4141: 110V Power Supply for IMx-Rail (for CMON 4116-R-110)
CMON 4142: External antenna for SKF Multilog IMx-Rail/IMx-16Plus
2.7.3 Performance over Time
No significant performance degradation over time, is expected for the IMx-Rail
hardware.