![SKC QuickTake 30 Operating Instructions Manual Download Page 20](http://html1.mh-extra.com/html/skc/quicktake-30/quicktake-30_operating-instructions-manual_1286857020.webp)
19
Advanced Setup
Intermittent Sampling
Intermi
tt
ent Sampling allows the pump to be programmed to run for a speci
fi
c
number of minutes up to 999, to shut o
ff
for a programmed
length of time, and to continue sampling on and o
ff
for a
predetermined number of cycles (e.g., program the pump
to run three cycles (n) of 15 minutes each (r) with a
fi
ve-
minute delay (d) between each cycle).
Entering Intermittent Sampling Mode
Press
or
to scroll to In
tt
. Press
to enter the intermi
tt
ent sampling setup mode.
Setting Run Time (r)
1. Press
or
to increase or decrease run time. The display will
fl
ash. If no
change to run time is desired, press
to move to delay time.
2. When
fi
nished, press
. Stor will
fl
ash on the display.
To save the new se
tt
ing:
Press [
]. Press
to move
to delay time setup.
To ignore the new se
tt
ing:
Press
. Display will move
to the delay time.
If displayed values are not changed, the
fl
ashing Stor
will not appear and pressing
will move the display
to the next parameter to be set.
Digital display:
Intermittent Sampling
Digital display:
Set run time
Setting Delay Time (d)
1. Press
or
to increase or decrease delay time. The
display will
fl
ash. If no change to delay time is desired,
press
to move to number of cycles.
2. When
fi
nished, press
. Stor will
fl
ash on the display.
To save the new se
tt
ing:
Press [
]. Press
to move
to number of cycles setup.
To ignore the new se
tt
ing:
Press
. Display will move to the number of cycles.
Digital display:
Set delay time