Mounting the Transceiver Unit
The Transceiver Unit should be installed in a dry place and consideration should be given to
accessibility for servicing. It is important to provide plenty of airspace on the sides for adequate fan
driven air circulation through the unit . Figures - shows the outer dimensions, mounting possibilities
and the minimum distances to other objects ensuring good cooling, as well as a drilling plan.
1) Space for airflow: min. 200
2) Space for cable and airflow: min. 25
3) Space for service access: min. 1000
Dimensions are in mm
Tolerance: +/- 1 mm
Weight without optional AC power supply: 19.5 Kg
Weight with optional AC power supply: 21 Kg
Centre of gravity
Doc.: 4-0-34091
fig.7
Bulkhead mounting
fig.6
Mounting options
MOUNTING THE UNITS
INSTALLATION
TRP 9250 TECHNICAL MANUAL
3-7