MULTIPLE CONTROL UNITS
Up to 5 DCU 9000 control units may be connected simultaneously to a DU 9000. One of the
control units may be given priority (by configuration).
Only one control unit can be
active at a time while all others are passive. When switching on, the
control unit on which the SUPPLY ON/OFF button was pressed becomes
active. After an
interruption in external power supply all control units will be
passive.
If the active control unit is in the MAIN-MENU, STATUS or RX-CALL states or if all control units
are passive, the display of a passive control unit shows:
If the active control unit is in any other state the display of a passive control unit shows:
Only a passive control unit with higher priority can interrupt the active control unit in this case.
Only the keys
,
,
,
and
are functioning on a
passive control unit.
An incoming call activates the visual and audible indicators of all control units. Light and sound
levels are induvidually adjustable.
The RX-CALL is displayed only on the active control unit.
STAND-BY
>STATUS<
BUSY
DSC OPERATION
KEYS AND INDICATORS
4-6
TRP 9250 TECHNICAL MANUAL
Summary of Contents for TRP 9250 S
Page 1: ...TRP 9250 Series Radio Transceiver for MF HF Technical Manual ...
Page 3: ...INTRODUCTION 1 2 TRP 9250 TECHNICAL MANUAL ...
Page 13: ...OPERATION 2 OPERATION Table of Contents 2 2 TRP 9250 TECHNICAL MANUAL ...
Page 69: ...INSTALLATION 3 INSTALLATION Table of contents 3 2 TRP 9250 TECHNICAL MANUAL ...
Page 95: ...INSTALLATION 3 28 TRP 9250 TECHNICAL MANUAL ...
Page 133: ...DSC 9000 FRONT PANEL DSC OPERATION DSC 9000 FRONT PANEL 4 2 TRP 9250 TECHNICAL MANUAL ...
Page 203: ...DSC OPERATION 4 72 TRP 9250 TECHNICAL MANUAL ...
Page 205: ...DSC INSTALLATION 5 DSC INSTALLATION Table of Contents 5 2 TRP 9250 TECHNICAL MANUAL ...
Page 227: ...DSC INSTALLATION 5 24 TRP 9250 TECHNICAL MANUAL ...