Document NO.:RD-519-39-001 

 

   

Version: A    2018.04.20 

- 7 - 

 

 

                                   Live = Brown 

                                   Neutral = Blue 

                                   I/O= White 

 

 

 

 

Wire on alarm harness connected to:   

 

Brown wire --- Live wire of AC line   

 

Blue wire --- Neutral wire of AC line 

 

White  wire  ---  I/O signal as interconnect line of other    

Units in the multiple station set up (refer to Diagram 8).   

Mounting Instructions: 

 

After selecting the proper location for your smoke alarm, 

wiring the AC base  harness as described in the Wiring 

instructions (AC power should be turned off at this stage).

 

 

Remove  alarm  from the base  with screwdriver  (refer to 

Diagram 9).   

     

 

 

 

 

 

 

Hold  the  base  on the installation  position, mark 

installation hole of the base with pencil.   

 

Bore two installation holes on the sign with electric drill. 

Make diameter of holes is 5mm. Strike the two plastic 

plugs into holes with hammer. 

 

Attach the base to the plastic plugs and fix tightly with the 

screws into the plastic plugs.  (Refer to  Diagram 10  - 

installation sketch map).   

 

Connect the AC power cord to the base. 

 

Fix the battery into battery box. 

 

Fit the alarm on the base until matching well on the base. 

 

Turn on the AC power. The green LED should be lit when 
the alarm is operating from AC power. 

 

Test smoke alarm using test button. The alarm will sound 

3 short beeps –  1.5  seconds  pause. Then repeat  it until 

release the button. 

 

WARNING

: To prevent injury, this unit must be securely 

attached to  ceiling in accordance with the installation 

instructions. 

Service and Warranty: 

Company warrants to the original consumer. Purchase each 

new smoke alarm to be free from defects in material and 

workmanship under normal use and service for a period of 3 

years from the date of purchase. This warranty does not cover 

damage resulting from accident, misuse or abuse or lack of 

reasonable care of the product. In no case shall company be 

liable for any incidental or consequential damages for breach 

of this or any other warranty express or implied

whatever. 

The bad product can be mailed to the following address with 

a detail explanation of problem. 

You feel that your smoke alarm is defective in any way after 

reviewed this manual, do not tamper with the unit. Return it 

for servicing to:

 

Manufacturer:   

SITERWELL ELECTRONICS CO., LIMITED 

ADDRESS: NO.666 QINGFENG ROAD, JIANGBEI  

DISTRICT, NINGBO,ZHEJIANG PROVINCE

CHINA 

TEL: 0086-574-87729581 

FAX: 0086-574-87729581 

E-MAIL:[email protected] 

 

I

nstallation sketch map:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

           
                  

Diagram 10 

Diagram 9 

Diagram 8 

Summary of Contents for GS519

Page 1: ... as near to the living areas as possible and ensure the alarm is audible when the bedrooms are occupied Typical single storey dwelling with recommended Install a smoke alarm on the ceiling inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway more than 30 feet long install a smoke alarm at each end If there s a basement install a smoke alarm on the ba...

Page 2: ...on it is possible that the smoke alarm may fail at any time For this reason you must test the smoke alarm weekly and replace unit after 10 years Battery Specification Voltage DC 9V Alkaline Carbon Zinc Lithium battery Gold Peak GP1604S Carbon Zinc Battery Gold Peak GP1604A Alkaline Battery Raymax 6LR61 Alkaline Battery EVE CR9V P Lithium battery Voltage DC 3V Lithium battery GP Energy CR123A Lithi...

Page 3: ...ill flash every 8 seconds indicating the smoke alarm is in the alarm silencer Hush mode NOTE WEEKLY TESTING IS REQUIERED Alarm silence hush mode When you press same Test button for at least 5 seconds or until the unit sounds to active silence control the alarm will enter HUSH mode for approx 8 minutes Smoke alarms are designed to minimize false alarms Combustion particles from cooking may set off ...

Page 4: ...op approximately after 20 seconds has elapsed Note GS519 GS517E and GS518E can be interconnected Trouble shooting Problem Cause and Remedy The green LED does not light when AC power supply 1 Check the AC terminal and the power cord is properly connected to the smoke alarm 2 If the problem still exists please it return to your retailer 3 If the unit is out of warranty please replace another new ala...

Page 5: ... not to open the door if the door is hot Teach household members to crawl along the floor to stay below dangerous smoke fumes and gases Practice a fire drill at least every six months including fire drills at night Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergen...

Page 6: ...ween 500mm and 1500mm from the highest point of the ceiling See Diagram 5 For single floor plan and multiple floor plan please refer to Diagram 6 Diagram 6 Wiring Instructions The appropriate power source is 220 240V single phase supplied When install or remove the smoke alarm you must turn off the AC power to ensure safety Connecting wires are recommended to use a cross sectional area from 0 8 mm...

Page 7: ... should be lit when the alarm is operating from AC power Test smoke alarm using test button The alarm will sound 3 short beeps 1 5 seconds pause Then repeat it until release the button WARNING To prevent injury this unit must be securely attached to ceiling in accordance with the installation instructions Service and Warranty Company warrants to the original consumer Purchase each new smoke alarm ...

Reviews: