9. Product specifications

Model: 

GS883-A

Product standards: 

EN 14604:2005/AC:2008 

                 EN 50291-1:2018

Type of apparatus: 

Type B - to provide a visual and

audible alarm only

Power Supply: 

3V    (CR17450) (non-replaceable, 

sealed-in battery up to 10 years lifetime)

Sensor of Smoke: 

photoelectric reflection

Smoke Alarm Sensitivity: 

0.096~0.146 dB/m

Smoke alarm silence: 

about 10 minutes

Sensor of CO: 

electrochemical

CO alarm sensitivity Setting: 
       

Conforms to EN 50291-1:2018

     30PPM     Without alarm before 120 minutes
     50PPM     Between 60 to 90 minutes
     100PPM    Between 10 to 40 minutes
     300PPM    Less than 3 minutes

Product life:

 10 years after manufacture

Standby Current: 

<20µA (average)

Alarm Current: 

<25mA (average)

Operation Ambient Condition:

 0~+40

30~93%RH non-condensing

Storage/Transport Ambient Condition: 

-

20~+50

, 10~95% RH non-condensing

Alarm sound : 

≥85dB at 10ft @3.0±0.5kHz

Low Battery warning silence: 

about 9 hours

Installation Location: 

ceiling or wall

Detection range:

 Max. 40 m

2

 within a room.

Size: 

about

 

Φ134*40mm

Weight:

 185±10g (net)

NOTE: This Combo Smoke/CO alarm is designed 
to detect carbon monoxide gas from any source of
combustion. It is not designed to detect any other
gas.

10. Deactivation of the device      

   

WARNING!-

 

Deactivation of the device is 

permanent. Once the device has been deactivated,
it cannot be reactivated!

 

   

WARNING!-

 

Once deactivated, the device 

will no longer detect smoke and CO.

   

WARNING!-

 

Once the device is deactivated

the battery will be depleted and the alarm will no
longer function.

   

WARNING!-

 

Once the device has been 

deactivated, it cannot be re-mounted.

     

CAUTION! 

- It only takes up to 96 hours 

for the battery to be fully discharged.

10.1 For un-installation remove the device from the 

bracket on the ceiling.

10.2 Break through the label with a screwdriver to 

remove pin.

10.3 Insert the pin into the hole through label.

     Remove pin             Pin               Insert pin

The WEEE symbol means that this product          
and battery must be disposed separately           
from other household waste.

When product reaches its end of life, take them to
a designated waste collection point in your area to
guarantee a safe disposal or recycling. Protect the
environment, human health and natural 
resources!

11. Good safety habits - develop 

and       practice a plan of 

escape          

.

             

12

 / 

14                      

GS883-A Instruction Manual Rev. G

Summary of Contents for GS883-A

Page 1: ...e long beeps repeating every 1 5 seconds The ALARM indicator red will flash the same pattern The smoke alarm takes precedence when both smoke and carbon monoxide are present 1 1 What to do in case of fire 1 Do not panic stay calm 2 Leave the building as quickly as possible Touch doors to feel if they are hot do not open but use an alternate exit that is not hot Crawl along the floor and do not sto...

Page 2: ...r the national Gas Emergency Service Provider if appropriate so that the source of carbon monoxide emissions can be identified and corrected Unless the reason for the alarm is obviously spurious do not use the fuel burning appliances again until they have been checked and cleared for use by a competent person according to national regulations If problems are identified during this inspection have ...

Page 3: ...oke CO alarm will not promptly detect a fire or CO danger except in the area or room in which it is installed 6 This Combo Smoke CO alarm may not alert every household member every time The alarm horn is loud in order to alert individuals to a potential danger However there may be some circumstances where a household member may not hear the alarm i e outdoor or indoor noise sound sleepers drug or ...

Page 4: ...d i e portable heaters or humidifiers 5 L o c a t e 1 0 f e e t a w a y f r o m a l appliances 6 Placing at eye level allows for optimum monitoring of the red and green indicator lights 7 Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the centre of the room places it closest to all points in the room Ceiling mounting is pre...

Page 5: ...ombustion are present when you start your automobile 8 In an enclosed space for example in a cupboard or behind a curtain 9 Where it can be obstructed for example by furniture 10 Less than 4 inch 10cm from the peak of an A frame type ceiling 11 Near fluorescent lights Electronic noise may cause nuisance alarms 12 Place out of the reach of children Under no circumstances should children be allowed ...

Page 6: ...m status of the smoke alarm or CO alarm 4 TEST SILENCE button The TEST SILENCE button is used to test the device and to silence the unit during a smoke alarm Press and hold to enable TEST function Or press to enable SILENCE function 5 Sounder The sounder is used to send out smoke alarm CO alarm warning and abnormal warning information 6 Power on switch The power on switch is used to power on the d...

Page 7: ...sing the TEST SILENCE button it will come into a low battery voltage warning silence status for about 9 hours and FAULT indicator yellow continue to flash NOTE The silence feature of low battery voltage warning is temporary action to cancel warning sound effect you need to replace the device as possible as soon 6 Smoke alarm When the device detects a dangerous level of smoke the device will emit a...

Page 8: ...If the CO alarm sounds and it is not being tested it means the unit is sensing a dangerous level of CO THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION 9 Human alarm sounds If the device enters into the status of smoke alarm or C O a l a r m t h e d e v i c e w i l l s t a r t i n a l o w e volume 85dB for around 10 seconds then emits a normal alarm volume 85dB This avoids start...

Page 9: ...vice chirps twice with FAULT indicator yellow flashing twice every 40 seconds LOW BATTERY VOLTAGE SIGNAL The battery is under low battery status please replace the device The device sounds unwanted alarms when residents are cooking taking showers etc 1 Press TEST SILENCE button to pause alarm 2 Clean the smoke around the device 6 General maintenance To keep your Combo Smoke CO alarm in good workin...

Page 10: ...ration state after several hours However the rate at which the equilibrium is reached depends on many factors e g lung ventilation rate physical activity and alveolar capillary transfer cardiac parameters blood haemoglobin concentration barometric pressure oxygen and carbon dioxide concentration in the inhaled air but the two most important factors in determining the COHb level are the CO concentr...

Page 11: ...w levels of COHb of between 0 3 and 0 7 present within the body These levels are considered neither beneficial nor harmful 7 4 Tobacco smoking Tobacco smokers are exposed to significant concentrations of CO In cigarette smokers the COHb concentration varies between 5 9 while heavy cigar smokers may exceed 10 WARNING Exposure to high levels of carbon monoxide can be fatal or cause permanent damage ...

Page 12: ...ours Installation Location ceiling or wall Detection range Max 40 m2 within a room Size about Φ134 40mm Weight 185 10g net NOTE This Combo Smoke CO alarm is designed to detect carbon monoxide gas from any source of combustion It is not designed to detect any other gas 10 Deactivation of the device WARNING Deactivation of the device is permanent Once the device has been deactivated it cannot be rea...

Page 13: ...ergency 12 Manufacturer and customer service information 12 1 Manufacturer SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086 574 87729581 FAX 0086 574 87729581 E MAIL sales china siter com 12 2 Customer service SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086...

Page 14: ...ce NOTE The warranty does not cover the batteries supplied 14 Warranty card Last Name First Name Phone Address City Country Zip Code Fault description Date of purchase Signature 14 14 GS883 A Instruction Manual Rev G ...

Reviews: