background image

(TEST/SILENCE button) is extremely useful in a 
kitchen area or other areas prone to nuisance 
alarms. The silence feature is to be used only when a
known alarm condition, such as smoke from cooking
activates the alarm. The device is desensitized by 
pressing the TEST/SILENCE button on the smoke 
alarm cover, the device will silence to indicate that 
the device is in a temporarily desensitized 
condition.
The Combo Smoke/CO alarm will automatically 
reset after approx. 10 minutes, if after this period, 
particles of combustion are still present, the alarm 
will sound again.
T h e   s m o k e   a l a r m   s i l e n c e   ( s m o k e   a l a r m   s i l e n c e
mode)  can  be  r epeate dly  used  unt il   t he ai r  has   been
cleared of the condition causing the alarm.

     

CAUTION!

 -Before using the smoke alarm 

silence (silence), identify the source of the smoke 
and be certain a safe condition exists.

8. CO alarm

When the device detects a dangerous level of CO, 
the device will emit a loud alarm pattern. The alarm 
signal pattern is 4 long beeps followed by 5 seconds
of silence. This cycle repeats as long as a dangerous
CO condition exists. The ALARM indicator (red) 
will flash the same pattern. This signal will repeat 
until dissipation of CO. 

CO alarm sensitivity Setting: 
       

Conforms to EN 50291-1:2018

     30PPM     Without alarm before 120 minutes
     50PPM     Between 60 to 90 minutes
     100PPM    Between 10 to 40 minutes
     300PPM    Less than 3 minutes

NOTE: The smoke alarm takes precedence when 
both
smoke and carbon monoxide are present.

    CAUTION!

 -Refer to “2. What to do if the 

CO alarm sounds” when you hear the sounds of 
the CO alarm warning.

     

DANGER! -

If the CO alarm sounds, and it 

is not being tested, it means the unit is sensing a 
dangerous level of CO, THE SOUND OF THE 
ALARM REQUIRES YOUR IMMEDIATE 

ATTENTION AND ACTION.  

9. Human alarm sounds

If the device enters into the status of smoke alarm or
C O   a l a r m ,   t h e   d e v i c e   w i l l   s t a r t   i n   a   l o w e r   a l a r m
volume (<85dB) for around 10 seconds, then emits a
normal alarm volume (≥85dB). This avoids startling
people.

10. Test the device

To test the device, pressing TEST/SILENCE button, 
you should hear alarm sound patterns and with a 
corresponding ALARM indicator (red) flashes. The 
alarm sound patterns will stop after  releasing TEST/
SILENCE button.
The test alarm sound pattern includes: 3 long beeps,
1.5 seconds pause, 4 long beeps, 5 seconds pause, 
repeat this pattern until releasing TEST/SILENCE 
button.

NOTE: After the TEST/SILENCE button is 
enabled, the alarm sounds and the red alarm light
flashes. This does not indicate that CO is present.

NOTE: Test the unit weekly! If at any time your 
unit does not perform as described, replace it 
immediately. 

NOTE: The function of human alarm sounds will 
enable for button test. Please press and hold test 
button more than 10 second, the device will emit a
normal alarm volume (

85dB).

     

WARNING! -

Do NOT use an open flame to

test your alarm, it could damage the alarm or 
ignite combustible materials and start a 
structural fire.

     

WARNING! -

Due to the loudness (85 

decibels) of the alarm, Always stand an arms-
length away from the unit when testing.

 

11. End of life warning

If the product continues to work for 10 years, the 
device will chirp 3 times every 40 seconds, with a 
FAULT indicator (yellow) flash, it indicates this 
Combo alarm is in end of life. That means your 
device has no detecting feature and no response to 
smoke and CO.

             

8

 / 

14                      

GS883-A Instruction Manual Rev. G

Summary of Contents for GS883-A

Page 1: ...e long beeps repeating every 1 5 seconds The ALARM indicator red will flash the same pattern The smoke alarm takes precedence when both smoke and carbon monoxide are present 1 1 What to do in case of fire 1 Do not panic stay calm 2 Leave the building as quickly as possible Touch doors to feel if they are hot do not open but use an alternate exit that is not hot Crawl along the floor and do not sto...

Page 2: ...r the national Gas Emergency Service Provider if appropriate so that the source of carbon monoxide emissions can be identified and corrected Unless the reason for the alarm is obviously spurious do not use the fuel burning appliances again until they have been checked and cleared for use by a competent person according to national regulations If problems are identified during this inspection have ...

Page 3: ...oke CO alarm will not promptly detect a fire or CO danger except in the area or room in which it is installed 6 This Combo Smoke CO alarm may not alert every household member every time The alarm horn is loud in order to alert individuals to a potential danger However there may be some circumstances where a household member may not hear the alarm i e outdoor or indoor noise sound sleepers drug or ...

Page 4: ...d i e portable heaters or humidifiers 5 L o c a t e 1 0 f e e t a w a y f r o m a l appliances 6 Placing at eye level allows for optimum monitoring of the red and green indicator lights 7 Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the centre of the room places it closest to all points in the room Ceiling mounting is pre...

Page 5: ...ombustion are present when you start your automobile 8 In an enclosed space for example in a cupboard or behind a curtain 9 Where it can be obstructed for example by furniture 10 Less than 4 inch 10cm from the peak of an A frame type ceiling 11 Near fluorescent lights Electronic noise may cause nuisance alarms 12 Place out of the reach of children Under no circumstances should children be allowed ...

Page 6: ...m status of the smoke alarm or CO alarm 4 TEST SILENCE button The TEST SILENCE button is used to test the device and to silence the unit during a smoke alarm Press and hold to enable TEST function Or press to enable SILENCE function 5 Sounder The sounder is used to send out smoke alarm CO alarm warning and abnormal warning information 6 Power on switch The power on switch is used to power on the d...

Page 7: ...sing the TEST SILENCE button it will come into a low battery voltage warning silence status for about 9 hours and FAULT indicator yellow continue to flash NOTE The silence feature of low battery voltage warning is temporary action to cancel warning sound effect you need to replace the device as possible as soon 6 Smoke alarm When the device detects a dangerous level of smoke the device will emit a...

Page 8: ...If the CO alarm sounds and it is not being tested it means the unit is sensing a dangerous level of CO THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION 9 Human alarm sounds If the device enters into the status of smoke alarm or C O a l a r m t h e d e v i c e w i l l s t a r t i n a l o w e volume 85dB for around 10 seconds then emits a normal alarm volume 85dB This avoids start...

Page 9: ...vice chirps twice with FAULT indicator yellow flashing twice every 40 seconds LOW BATTERY VOLTAGE SIGNAL The battery is under low battery status please replace the device The device sounds unwanted alarms when residents are cooking taking showers etc 1 Press TEST SILENCE button to pause alarm 2 Clean the smoke around the device 6 General maintenance To keep your Combo Smoke CO alarm in good workin...

Page 10: ...ration state after several hours However the rate at which the equilibrium is reached depends on many factors e g lung ventilation rate physical activity and alveolar capillary transfer cardiac parameters blood haemoglobin concentration barometric pressure oxygen and carbon dioxide concentration in the inhaled air but the two most important factors in determining the COHb level are the CO concentr...

Page 11: ...w levels of COHb of between 0 3 and 0 7 present within the body These levels are considered neither beneficial nor harmful 7 4 Tobacco smoking Tobacco smokers are exposed to significant concentrations of CO In cigarette smokers the COHb concentration varies between 5 9 while heavy cigar smokers may exceed 10 WARNING Exposure to high levels of carbon monoxide can be fatal or cause permanent damage ...

Page 12: ...ours Installation Location ceiling or wall Detection range Max 40 m2 within a room Size about Φ134 40mm Weight 185 10g net NOTE This Combo Smoke CO alarm is designed to detect carbon monoxide gas from any source of combustion It is not designed to detect any other gas 10 Deactivation of the device WARNING Deactivation of the device is permanent Once the device has been deactivated it cannot be rea...

Page 13: ...ergency 12 Manufacturer and customer service information 12 1 Manufacturer SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086 574 87729581 FAX 0086 574 87729581 E MAIL sales china siter com 12 2 Customer service SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086...

Page 14: ...ce NOTE The warranty does not cover the batteries supplied 14 Warranty card Last Name First Name Phone Address City Country Zip Code Fault description Date of purchase Signature 14 14 GS883 A Instruction Manual Rev G ...