background image

NOTE: You need to replace the device as soon as 
possible when the device enters this status. 

NOTE: Refer to “10. Deactivation of the device” 
to dispose the device.

5.3 Troubleshooting

     

CAUTION! 

-Do not attempt to repair the 

device. It will affect your warranty.

If the device is not operating properly, and is still 
under warranty, return it to the place of purchase. 
Pack it in a well-padded carton, and ship to the place
of purchase. 
If the alarm is no longer under warranty, have a 
licensed electrician replace it immediately with a 
comparable alarm.

Table 5.3 Troubleshooting guide:

Problem

Method of disposal

The device does 
not sound 

when 

TEST/SILENCE 
is pressed.

1. 

Ensure device is powered 

off.

  Fit the device on the bracket 

and turn it clockwise, until 
matching well on the bracket.

2. The device is under "Smoke 

alarm silence" or "Low battery 
voltage warning silence" or 
"Fault warning" mode.

  Please ensure the device is 

under "Normal operation" mode
then test the device.

3. Clean the device. Please refer 

to "6. General maintenance".

4. If there are still failures 

during warranty, you can return
it to your retailer.

5. If the unit is out of warranty, 

please 

replace with another new

device.

The device chirps 
once with FAULT 
indicator (yellow) 
flashing once 
every 40 seconds. 

MALFUNCTION SIGNAL

Clean this device. Please refer to
"6. General maintenance ". 
1. If the device is under 

warranty, please return it to 
your retailer for replacement.

2. If the device is out of 

warranty, please replace with 

another new device.

The device chirps 
twice with FAULT
indicator (yellow) 
flashing twice 
every 40 seconds.

LOW BATTERY VOLTAGE 
SIGNAL
T he   ba t t e ry  i s  un de r  l ow  b a t t e r y
status, please replace the device.

The device sounds
unwanted alarms 
when residents are
cooking, taking 
showers, etc.

1. Press TEST/SILENCE button 

to pause alarm.

2. Clean the smoke around the 
device.

6. General maintenance             

To keep your Combo Smoke/CO alarm in good 
working order, please follow these simple steps:
1 .   V e r i f y   t h e   u n i t ' s   a l a r m   s o u n d   a n d   i n d i c a t o r s

o p e r a t i o n   b y  

p r e s s i n g

  t h e   T E S T / S I L E N C E   b u t t o n

once a week.

2. Remove the unit from the ceiling and clean the 

alarm cover and vents with a soft brush attachment
once a month to remove dust and dirt.

3. Never use detergents or other solvents to clean 
the unit.
4. Avoid spraying air fresheners, hair spray, or other

aerosols near the device.

5. Do not paint the device. Paint will seal the vents 

and interfere with the sensor's ability to detect CO.
Never attempt to disassemble the unit or clean 
inside. This action will void your warranty.

6. As soon as possible, place the Combo Smoke/CO 

alarm back in its proper location to assure 
continuous protection from fire and carbon 
monoxide poisoning. 

7. When household cleaning supplies or similar 

contaminants are used, the area should be 
ventilated.

      

WARNING! -

The following substances can

affect the sensor and may cause false actions: 
methane, propane, isobutene, isopropanol, 
ethylene, benzene, toluene, ethyl acetate, 
hydrogen sulfide, sulfur dioxides, alcohol based 
products, paints, thinner, solvents, adhesives, hair
sprays, after shaves, perfumes and some cleaning 
agents. 

    WARNING! -

Your Combo Smoke/CO alarm

             

9

 / 

14                      

GS883-A Instruction Manual Rev. G

Summary of Contents for GS883-A

Page 1: ...e long beeps repeating every 1 5 seconds The ALARM indicator red will flash the same pattern The smoke alarm takes precedence when both smoke and carbon monoxide are present 1 1 What to do in case of fire 1 Do not panic stay calm 2 Leave the building as quickly as possible Touch doors to feel if they are hot do not open but use an alternate exit that is not hot Crawl along the floor and do not sto...

Page 2: ...r the national Gas Emergency Service Provider if appropriate so that the source of carbon monoxide emissions can be identified and corrected Unless the reason for the alarm is obviously spurious do not use the fuel burning appliances again until they have been checked and cleared for use by a competent person according to national regulations If problems are identified during this inspection have ...

Page 3: ...oke CO alarm will not promptly detect a fire or CO danger except in the area or room in which it is installed 6 This Combo Smoke CO alarm may not alert every household member every time The alarm horn is loud in order to alert individuals to a potential danger However there may be some circumstances where a household member may not hear the alarm i e outdoor or indoor noise sound sleepers drug or ...

Page 4: ...d i e portable heaters or humidifiers 5 L o c a t e 1 0 f e e t a w a y f r o m a l appliances 6 Placing at eye level allows for optimum monitoring of the red and green indicator lights 7 Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the centre of the room places it closest to all points in the room Ceiling mounting is pre...

Page 5: ...ombustion are present when you start your automobile 8 In an enclosed space for example in a cupboard or behind a curtain 9 Where it can be obstructed for example by furniture 10 Less than 4 inch 10cm from the peak of an A frame type ceiling 11 Near fluorescent lights Electronic noise may cause nuisance alarms 12 Place out of the reach of children Under no circumstances should children be allowed ...

Page 6: ...m status of the smoke alarm or CO alarm 4 TEST SILENCE button The TEST SILENCE button is used to test the device and to silence the unit during a smoke alarm Press and hold to enable TEST function Or press to enable SILENCE function 5 Sounder The sounder is used to send out smoke alarm CO alarm warning and abnormal warning information 6 Power on switch The power on switch is used to power on the d...

Page 7: ...sing the TEST SILENCE button it will come into a low battery voltage warning silence status for about 9 hours and FAULT indicator yellow continue to flash NOTE The silence feature of low battery voltage warning is temporary action to cancel warning sound effect you need to replace the device as possible as soon 6 Smoke alarm When the device detects a dangerous level of smoke the device will emit a...

Page 8: ...If the CO alarm sounds and it is not being tested it means the unit is sensing a dangerous level of CO THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION 9 Human alarm sounds If the device enters into the status of smoke alarm or C O a l a r m t h e d e v i c e w i l l s t a r t i n a l o w e volume 85dB for around 10 seconds then emits a normal alarm volume 85dB This avoids start...

Page 9: ...vice chirps twice with FAULT indicator yellow flashing twice every 40 seconds LOW BATTERY VOLTAGE SIGNAL The battery is under low battery status please replace the device The device sounds unwanted alarms when residents are cooking taking showers etc 1 Press TEST SILENCE button to pause alarm 2 Clean the smoke around the device 6 General maintenance To keep your Combo Smoke CO alarm in good workin...

Page 10: ...ration state after several hours However the rate at which the equilibrium is reached depends on many factors e g lung ventilation rate physical activity and alveolar capillary transfer cardiac parameters blood haemoglobin concentration barometric pressure oxygen and carbon dioxide concentration in the inhaled air but the two most important factors in determining the COHb level are the CO concentr...

Page 11: ...w levels of COHb of between 0 3 and 0 7 present within the body These levels are considered neither beneficial nor harmful 7 4 Tobacco smoking Tobacco smokers are exposed to significant concentrations of CO In cigarette smokers the COHb concentration varies between 5 9 while heavy cigar smokers may exceed 10 WARNING Exposure to high levels of carbon monoxide can be fatal or cause permanent damage ...

Page 12: ...ours Installation Location ceiling or wall Detection range Max 40 m2 within a room Size about Φ134 40mm Weight 185 10g net NOTE This Combo Smoke CO alarm is designed to detect carbon monoxide gas from any source of combustion It is not designed to detect any other gas 10 Deactivation of the device WARNING Deactivation of the device is permanent Once the device has been deactivated it cannot be rea...

Page 13: ...ergency 12 Manufacturer and customer service information 12 1 Manufacturer SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086 574 87729581 FAX 0086 574 87729581 E MAIL sales china siter com 12 2 Customer service SITERWELL ELECTRONICS CO LIMITED ADDRESS No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China TEL 0086...

Page 14: ...ce NOTE The warranty does not cover the batteries supplied 14 Warranty card Last Name First Name Phone Address City Country Zip Code Fault description Date of purchase Signature 14 14 GS883 A Instruction Manual Rev G ...