20
APPENDIX
Transmitter
The life span of the remote control batteries depends on
various factors: quality of the batteries used, the number
of ignitions of the appliance, the number of changes to the
room thermostat set point, etc.
When the transmitter batteries are low, an Icon will appear
on the LCD display of the transmitter (Fig. 25) before all
battery power is lost. When the batteries are replaced this
Icon will disappear.
IFC Board (back up batteries)
The life span of the IFC batteries depends on various factors: quality of the batteries used, the
number of ignitions of the appliance, the number of changes to the room thermostat set point,
etc.
When the IFC batteries are low, a "double-beep” will be emitted from the IFC board when it
receives a command from the transmitter. This is an alert for a low battery condition for the IFC
board. When the batteries are replaced the “beep” will be emitted from the IFC board when a key
is pressed (See Initialization of The System).
Low Battery Power indicator
Fig. 25
Command defi nitions
Main ON/OFF
switch
Pilot IPI / CPI
switch
Transmitted
command
Command reference
name
Commanded Fireplace
State
Any position
Opened, IPI
“OFF” + “IPI”
Turn-OFF
Flames OFF
Closed,
Main ON
enable
Opened, IPI
“ON” + “IPI”
or
“ON” + “CPI”
Turn-ON
Pilot + Main burner
fl ames ON
Any position
Closed, CPI
“OFF” + “CPI”
Pilot-ON
Pilot fl ame ON
Closed,
Main ON
enable
Closed, CPI
“ON” + “IPI”
or
“ON” + “CPI”
Turn-ON
Pilot + Main burner
fl ames ON
Opened,
Main ON
disable
Closed, CPI
“CPI”
“IPI”
Pilot-ON
Turn-OFF
Pilot fl ame ON
Flames OFF
Opened,
Main ON
disable
Opened, IPI
Any command &
Mode
Turn-OFF
Flames OFF