background image

7

IFC MODULE

Fig. 3: 

Proflame 2 IFC Board.

The Profl ame 2 Integrated Fireplace Control (IFC) board is a device that allows the automatic 

ignition and pilot fl ame supervision, to command the functions of a hearth appliance, see fi g.3.

It’s confi gured to control the ON/OFF main burner operation, giving the choice of both IPI 

(intermittent pilot ignition), and CPI (continuous pilot ignition) modes.

The Profl ame 2 IFC board controls and connects directly to the pilot assembly and an automatic 

valve of the Profl ame 880, 886 and 885 families using low electric power.

The IFC Board can be powered by an AC and battery pack for back up (ATMO Systems only).

The Profl ame 2 offers the added ability to control the comfort fan speed from OFF through six (6) 

speeds, a remotely actuated auxiliary outlet and a dimmable light outlet. The external batteries can 

provide DC power to the IFC allowing the batteries to be used only when line power is interrupted 

or lost, and if the appliance does not use a combustion fan.

PILOT

1116690

0584922

0584921

0584920 / 0584924

Summary of Contents for PROFLAME 2 Basic

Page 1: ...ADVANCED REMOTE CONTROL SYSTEMS PROFLAME 2 Basic Standard Complete 9 955 116 02 Subject to change without notice w w w s i t g r o u p i t ...

Page 2: ... Basic Proflame 2 system the control of On Off and flame height adjustment operation of the main burner allows to operate a Split Flow dual burner control The Standard Proflame 2 system is specifically developed to be used together with the Proflame 885 valve and provides for battery back up in the event of line power loss The Complete Proflame 2 is a remote controls system that directs multiple f...

Page 3: ...tion Gas Control BASIC PROFLAME 2 STANDARD PROFLAME 2 e r PROFLAME Transmitter IFC M E F L A M 885 PROFLAME Combination Gas Control SPLIT FLOW COMPLETE PROFLAME 2 FAN LIGHT LOCAL USER INTERFACE P R O F L A M F IFC P R O F L A M F OPTIONAL EXTERNAL RF RECEIVER OPTIONAL PROFLAME TRANSMITTER S P E C I F I C I F C C O D E A V A I L A B L E O N R E Q U E S T ...

Page 4: ...ation 6 levels Referring to the remote control 1 TMFSLA indicates enabled function Thermostat Modulator flame Fan Split flow Lights modulation Auxiliary output 2 TMFSL indicates enabled function Thermostat Modulator flame Fan Split flow Lights modulation 3 TMFL indicates enabled function Thermostat Modulator flame Fan Lights modulation 4 CPI indicates Continous Pilot Ignition IPI indicates Intermi...

Page 5: ...ompatible 3 Wiring harness to connect the IFC to the control switches and depending on the FAN ATMO configuration to the APS 4 Proflame 2 Transmitter 5 Pilot assembly 6 Split Flow valve optional 7 Comfort fan dimmable lights auxiliary device optional 8 In Fan configuration the combustion Fan with Air Pressure Switch APS safety device TECHNICAL DATA REMOTE CONTROL TRANSMITTER Supply voltage 4 5 V thre...

Page 6: ...h LCD Display The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD display Fig 1 A Mode Key is provided to index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Fig 1A 1B 2 Fig 1A Proflame 2 Transmitter Blue LCD display UP DOWN Arrow Key ON OFF Key THERMOSTAT Key MODE Key Fig 1B Proflame Wall Mount ...

Page 7: ... and connects directly to the pilot assembly and an automatic valve of the Proflame 880 886 and 885 families using low electric power The IFC Board can be powered by an AC and battery pack for back up ATMO Systems only The Proflame 2 offers the added ability to control the comfort fan speed from OFF through six 6 speeds a remotely actuated auxiliary outlet and a dimmable light outlet The external ba...

Page 8: ...of the device Make sure to attach the adapter in a level plane without any distortion Proceed as follow Wall mounting 1 Detach the adapter from the body of the remote control see Fig A 2 Position the adapter on the wall mark the points for the fixing holes and drill the wall 3 Fix the adapter on the wall using the mounting hardware supplied with the remote control 4 Insert the remote control onto ...

Page 9: ... the IFC 2 Install the IFC in the appliance using the screws Fig 4 3 Insert the 4 AA type batteries in the battery holder with the correct polarity 4 Connect the switches 5 Put the main switch in the OFF position open and the IPI CPI switch on IPI position open 6 Connect the wiring harnesses to the loads Fig 4 Proflame 2 IFC Board installation ...

Page 10: ... configuration The electrical connections must be in accordance to Fig 5 0 880 XXX 0 886 XXX 0 190 XXX 0 584 920 0 584 307 0 584 952 Fig 5 Proflame 2 BASIC IFC 880 886 PROFLAME wiring diagram GROUND Chassis connection 0 584 920 or 0 584 924 X5 X4 X3 X2 X1 ON OFF IPI CPI BATTERY PACK ...

Page 11: ...m Connecting to the 885 Gas Valve and IFC control board in COMPLETE configuration ATMO The electrical connections must be in accordance to Fig 7 0 584 951 0 584 040 GROUND Chassis connection 0 584 951 0 584 040 GROUND Chassis connection 0 584 920 or 0 584 924 X9 X8 X7 X6 X5 X4 X3 X2 X1 ON OFF IPI CPI BATTERY PACK LOCAL USER INTERFACE REMOTE CONTROL ADAPTER S P E C I F I C I F C C O D E A V A I L A...

Page 12: ... open the IFC removing the cover and than remove the jumper JP1 JP1 open see Picture and Table below JP1 STATUS IFC board enabled mode OPEN FAN CLOSED ATMO DEFAULT 0 885 XXX 0 190 XXX 0 584 951 0 584 92x 0 584 305 0 584 040 0 540 001 0 584 921 0 584 952 Fig 8 Proflame 2 COMPLETE FAN 885 PROFLAME wiring diagram 0 584 951 0 584 040 GROUND Chassis connection AUX COMFORT FAN LAMP BURNER 0 584 103 as a...

Page 13: ...on sequence for the Pilot Flame and then will remain with the Pilot Flame ON waiting for a command to ignite the Main Burner Flame Turning ON the Appliance Close the ON OFF command contact on the ON OFF wires and this will command the IFC ignition board to Turn ON the appliance main burner Turning OFF the Appliance Open the ON OFF command contact on the ON OFF wires and this will command the IFC i...

Page 14: ...osition Press the SW1 button on the IFC module The IFC will beep three 3 times to indicate that it is ready to synchronize with a Transmitter Install the 3 AAA type batteries in the battery bay located on the base of the Transmitter With the batteries already installed in the Transmitter push the ON button The Receiver will beep four times to indicate the Transmitter s command is accepted If a sec...

Page 15: ... Intermittent Pilot CPI IPI selection paragraph 15 Fig 8 Remote Control display Remote Flame Control The proflame has six 6 flame levels With the system on and the flame level at the maximum in the appliance pressing the Down Arrow Key once will reduce the flame height by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow ...

Page 16: ...een of the Transmitter Fig 11 Fig 10 Fig 11 SET TEMPERATURE ROOM TEMPERATURE Smart Thermostat Transmitter Operation The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function pre...

Page 17: ...Arrow Keys Fig 1 to turn on off or adjust the fan speed fig 15 A single beep will confirm reception of the command Fig 14 Fig 15 Remote dimmer control Light PROFLAME 2 COMPLETE only The function controls the power outlet by the dimmable light control To activate this function use the Mode Key fig 1 to index to the LIGHT icon fig 16 17 The intensity of the output can be adjusted through six 6 level...

Page 18: ...l turn the secondary burner off A single beep will confirm the reception of the command Fig 18 Fig 19 Remote auxiliary relay control PROFLAME 2 MFSLA only The auxiliary function controls the AUX relay outlet To activate this function use the Mode Key fig 1 to index to the AUX icon fig 20 21 Pressing the Up Arrow Key will activate the outlet Pressing the Down Arrow Key will turn the outlet off A si...

Page 19: ... to the CPI mode icon fig 22 23 Pressing the Up Arrow Key will activate the Continous Pilot Ignition mode CPI Pressing the Down Arrow Key will return to IPI A single beep will confirm the reception of the command NOTE If the system is equipped with a CPI IPI toggle switch Set the CPI IPI switch to CPI position switch closed to enable remote CPI selection Set the CPI IPI switch to IPI position swit...

Page 20: ...le beep will be emitted from the IFC board when it receives a command from the transmitter This is an alert for a low battery condition for the IFC board When the batteries are replaced the beep will be emitted from the IFC board when a key is pressed See Initialization of The System Low Battery Power indicator Fig 25 Command definitions Main ON OFF switch Pilot IPI CPI switch Transmitted command C...

Page 21: ...21 DIMENSIONAL DRAWINGS PROFLAME Transmitter 140 37 71 152 63 63 26 26 Ø3 Ø3 Dimensions are in millimeters PROFLAME Wall Mount Transmitter Dimensions are in millimeters ...

Page 22: ...22 DIMENSIONAL DRAWINGS IFC Control Board 173 7 164 90 5 Dimensions are in millimeters ...

Page 23: ...23 ...

Page 24: ...SIT S p A Viale dell Industria 31 33 35129 PADOVA ITALY Tel 39 049 829 31 11 Fax 39 049 807 00 93 www sitgroup it e mail mkt sitgroup it ...

Reviews: