The installer is able to set the equipment in order to execute sequential programs by entering the
“99” code
instead of entering the starting time and, the program number that will precede and initialize the current one in-
stead of entering the starting minute.
7.1.1. Alternating sequential programs
An alternating sequence permits the starting program in one sequential irrigation program to be alternated
with a different program in the sequence.
To do this, the installer must configure the option for sequential programs to be alternating ones, keeping in
mind that in this case the sequence is ordered from the lowest program number to the highest.
Using the previous section’s example, the first time the program starts it will start with program 10 and termi-
nate with 14; the next time the program is activated, it will start with 11 and terminate with 10, and so on.
First start
P10
P11
P12
P13
P14
Second start
P11
P12
P13
P14
P10
Third start
P12
P13
P14
P10
P11
Fourth start
P13
P14
P10
P11
P12
Fifth start
P14
P10
P11
P12
P13
Sixth start
P10
P11
P12
P13
P14
......
P11
...
...
The program consultation will display the text “Alternate start” to indicate which program starts in the next ac-
tivation. This information will be updated once the current irrigation sequence has terminated.
PROGRAM 10
Sectors: 05
SMTWTFS Start: 07:30
Irrigation: 02:08
PROGRAM 11
Sectors: 06
- - - - - - - Start: 99:10
Irrigation: 01:44
PROGRAM 12
Sectors: 07
- - - - - - - Start: 99:11
Irrigation: 01:55
PROGRAM 13
Sectors: 08
- - - - - - - Start: 99:12
Irrigation: 2:23