8.6 Electrical connection

X1

Electrical control panel

Open the front cover of the control panel to gain access to the terminal block for the electrical connec-
tions.

230V

AC 50/60Hz

Suction outlets /

 Inle

t

Suction start contact (MICRO)

central suction unit / 

Central vacuum

The complete schematic diagram is present inside the control panel.

Summary of Contents for AUTO Jet TURBIX

Page 1: ...Technical manual Manuel technique Manual t cnico Technisches Handbuch w w w s i s t e m a i r c o m MANUALE TECNICO F D CENTRAL VACUUM SYSTEMS ByTecnoplus s r l EN ES V 1 0 0...

Page 2: ......

Page 3: ...ding fixed guards 9 4 4 Safety measures regarding movable guards 8 5 INTENDED USE OF THE MACHINE 10 6 UNINTENDED USE OF THE MACHINE 10 7 EQUIPMENT AND ACCESSORIES 11 8 INSTALLATION 12 8 1 Positioning...

Page 4: ...orrect use of the equipment so that the best per formance is obtained while keeping it in perfect working order and safe condition No part of this document may be reproduced copied or disclosed by any...

Page 5: ...ection IP 44 Supply V ac 230 Absorption A 1 5 Container capacity l 76 Pneumatic actuator pressure Bar 6 Dust entry mm 80 Blowing motor exhaust outlet mm 80 Pressurized air inlet G 3 4 Nozzle pressure...

Page 6: ...tainless steel cyclone cone Stainless steel cylinder dust collection Nozzle solenoid valve Nozzle manifold Dust entrance connection Electric control panel Pressure regulator pneumatic actuator Load be...

Page 7: ...shell in AISI 304 stainless steel Pneumatic linear actuator Possibility to connect 8 compressed air nozzles Control panel for the blowing powder filling and dust discharge systems The pneumatic actua...

Page 8: ...anger and prohibition are found in the parts of the equip ment where if you do not comply with the conditions dictated by the warnings you can certainly create unsafe situations WARNINGS TECNOPLUS S R...

Page 9: ...of the electrical power supply 4 4 Safety relating to movable closure guards There are no movable closure guards each enclosure is considered as a fixed enclosure secured by special screws TECNOPLUS s...

Page 10: ...manufacturer Any use other than that for which the product was built represents an anomalous condition that can cause damage to the unit and constitute a serious danger for the user 5 INTENDED USE OF...

Page 11: ...ludes the accessories kit comprised of the following elements 1 N 1 AUTO Jet 2 N 2 rubber sleeves for connection to the suction tube network 3 N 4 metal clamps for fixing the sleeves 4 N 1 installatio...

Page 12: ...be installed in areas subject to high humidity possible flooding or high temperatures The AUTO Jet Turbix separator can be installed in service rooms or in service areas protected from bad weather hu...

Page 13: ...to be able to position the dust inlet fitting according to installation needs Unscrewing the 2 upper screws fixing to the frame plate and the 8 lower screws fixing to the cylinder it is possible to ro...

Page 14: ...unit and of the suction lines leading to the Auto Jet Turbix must be made giving consideration to the number of simultaneous users and the type of material to be vacuumed N B It is advisable to posit...

Page 15: ...w rate on the nozzles in order to assure their correct operation Install a tap for closing the compressed air and a drain valve for the safe maintenance of the appliance Pressure regulation applied to...

Page 16: ...ction X1 Electrical control panel Open the front cover of the control panel to gain access to the terminal block for the electrical connec tions 230VAC 50 60Hz Suction outlets Inlet Suction start cont...

Page 17: ...ed tanks in cisterns It is advisable to contact the Technical Office to best manage the use of this product with liquids 8 7 Application examples Solid residues powders The self supporting frame can b...

Page 18: ...this button it is possible to manually force a material discharge cycle thus checking that the AUTO Jet system is working correctly RED Potentiometer adjustment of the maximum interval time between o...

Page 19: ...the limits indicated in chapter 8 5 Set up a vacuum cycle to check its operation then before vacuuming the selected material check that there are no foreign bodies inside Verify that everything indic...

Page 20: ...damage resulting from 1 accident abuse misapplication repair alteration or unauthorized disassembly 2 maintenance operation use which is not in accordance with the product instructions or connection t...

Page 21: ...e il Fascicolo Tecnico Tecnoplus S r l Via Cilavegna 53 27020 Gravellona Lomellina Pv ITALIA Gravellona Lomellina 23 04 2018 Firma LINGUA ORIGINALE TECNOPLUS S r l Capitale Sociale 99 000 00 27020 Gra...

Page 22: ...Auto Jet Instruction Manual 22 19 04 2018 Rev 2 0 0 CENTRAL VACUUM SYSTEMS ByTecnoplus s r l...

Page 23: ......

Page 24: ...27020 Gravellona Lomellina PV ITALIA Via Cilavegna 53 GPS N 45 19 28 E 8 45 32 Tel 39 0381 650082 Fax 39 0381 650120 info sistemair com F0920548...