background image

Auto Jet Instruction Manual

4

    19/04/2018  Rev:2.0.0 

CENTRAL VACUUM SYSTEMS

ByTecnoplus 

s.r.l.

GENERAL INFORMATION

1. USING THE MANUAL

The instruction manual is a document written by the manufacturer and is an integral part of the central 
vacuum unit. In the event that it is resold, given or rented to others, it must be handed to the new user 
or owner.
It is recommended to use it and store it carefully during its entire service life.
The main objective of this manual is to indicate the correct use of the equipment, so that the best per-
formance is obtained,  while keeping it in perfect working order and safe condition.
No part of this document may be reproduced, copied or disclosed by any means without the written 
permission of TECNOPLUS s.r.l. owner of the SISTEM AIR brand. The TECNOPLUS company s.r.l. 
reserves the right to make improvements or modifi cations to this manual and to this device at any time, 
without the obligation to give prior notice to third parties.

To obtain the best results, the use of original  SISTEM AIR consumables is recommended

The SISTEM AIR trademark mentioned in this manual is a registered trademark and belongs to to the

owner TECNOPLUS S.r.l.

Summary of Contents for AUTO Jet TURBIX

Page 1: ...Technical manual Manuel technique Manual t cnico Technisches Handbuch w w w s i s t e m a i r c o m MANUALE TECNICO F D CENTRAL VACUUM SYSTEMS ByTecnoplus s r l EN ES V 1 0 0...

Page 2: ......

Page 3: ...ding fixed guards 9 4 4 Safety measures regarding movable guards 8 5 INTENDED USE OF THE MACHINE 10 6 UNINTENDED USE OF THE MACHINE 10 7 EQUIPMENT AND ACCESSORIES 11 8 INSTALLATION 12 8 1 Positioning...

Page 4: ...orrect use of the equipment so that the best per formance is obtained while keeping it in perfect working order and safe condition No part of this document may be reproduced copied or disclosed by any...

Page 5: ...ection IP 44 Supply V ac 230 Absorption A 1 5 Container capacity l 76 Pneumatic actuator pressure Bar 6 Dust entry mm 80 Blowing motor exhaust outlet mm 80 Pressurized air inlet G 3 4 Nozzle pressure...

Page 6: ...tainless steel cyclone cone Stainless steel cylinder dust collection Nozzle solenoid valve Nozzle manifold Dust entrance connection Electric control panel Pressure regulator pneumatic actuator Load be...

Page 7: ...shell in AISI 304 stainless steel Pneumatic linear actuator Possibility to connect 8 compressed air nozzles Control panel for the blowing powder filling and dust discharge systems The pneumatic actua...

Page 8: ...anger and prohibition are found in the parts of the equip ment where if you do not comply with the conditions dictated by the warnings you can certainly create unsafe situations WARNINGS TECNOPLUS S R...

Page 9: ...of the electrical power supply 4 4 Safety relating to movable closure guards There are no movable closure guards each enclosure is considered as a fixed enclosure secured by special screws TECNOPLUS s...

Page 10: ...manufacturer Any use other than that for which the product was built represents an anomalous condition that can cause damage to the unit and constitute a serious danger for the user 5 INTENDED USE OF...

Page 11: ...ludes the accessories kit comprised of the following elements 1 N 1 AUTO Jet 2 N 2 rubber sleeves for connection to the suction tube network 3 N 4 metal clamps for fixing the sleeves 4 N 1 installatio...

Page 12: ...be installed in areas subject to high humidity possible flooding or high temperatures The AUTO Jet Turbix separator can be installed in service rooms or in service areas protected from bad weather hu...

Page 13: ...to be able to position the dust inlet fitting according to installation needs Unscrewing the 2 upper screws fixing to the frame plate and the 8 lower screws fixing to the cylinder it is possible to ro...

Page 14: ...unit and of the suction lines leading to the Auto Jet Turbix must be made giving consideration to the number of simultaneous users and the type of material to be vacuumed N B It is advisable to posit...

Page 15: ...w rate on the nozzles in order to assure their correct operation Install a tap for closing the compressed air and a drain valve for the safe maintenance of the appliance Pressure regulation applied to...

Page 16: ...ction X1 Electrical control panel Open the front cover of the control panel to gain access to the terminal block for the electrical connec tions 230VAC 50 60Hz Suction outlets Inlet Suction start cont...

Page 17: ...ed tanks in cisterns It is advisable to contact the Technical Office to best manage the use of this product with liquids 8 7 Application examples Solid residues powders The self supporting frame can b...

Page 18: ...this button it is possible to manually force a material discharge cycle thus checking that the AUTO Jet system is working correctly RED Potentiometer adjustment of the maximum interval time between o...

Page 19: ...the limits indicated in chapter 8 5 Set up a vacuum cycle to check its operation then before vacuuming the selected material check that there are no foreign bodies inside Verify that everything indic...

Page 20: ...damage resulting from 1 accident abuse misapplication repair alteration or unauthorized disassembly 2 maintenance operation use which is not in accordance with the product instructions or connection t...

Page 21: ...e il Fascicolo Tecnico Tecnoplus S r l Via Cilavegna 53 27020 Gravellona Lomellina Pv ITALIA Gravellona Lomellina 23 04 2018 Firma LINGUA ORIGINALE TECNOPLUS S r l Capitale Sociale 99 000 00 27020 Gra...

Page 22: ...Auto Jet Instruction Manual 22 19 04 2018 Rev 2 0 0 CENTRAL VACUUM SYSTEMS ByTecnoplus s r l...

Page 23: ......

Page 24: ...27020 Gravellona Lomellina PV ITALIA Via Cilavegna 53 GPS N 45 19 28 E 8 45 32 Tel 39 0381 650082 Fax 39 0381 650120 info sistemair com F0920548...