17 - TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
There is no suction from any of the
suction sockets
The power cable is
unplugged
Connect the power cable
The micro line cable is not
connected
Connect the activation cable
(sensor)
There is no air suction from just one
suction socket
The electric contacts are
interrupted or the micro-
switch of the suction socket is
out of order
Call the Technical Service
The air suction is weak
More than one suction socket
is being used at the same
time
Use only one suction inlet at
a time
The
fl
exible hose or the
cleaning accessories are
broken
Check the
fl
exible hose
and the accessories are not
damaged (change them if
necessary)
The dust bag is full
Change the dust bag
The sealing gasket of the
dust bin is damaged
Check sealing gasket
integrity
There is a clogging in the
suction pipes of the pipe
network
Call the Technical Service
The air exhaust outlet is
blocked
Call the Technical Service
The vacuum cleaner still works even
when the suction inlets are closed
Fault of the printed circuit
board
Call the Technical Service
Summary of Contents for 3100.0SM