Siruba 700LQ ECA Manual Download Page 13

S18

後感測器靈敏度

Back sensor sensitivity 
degree

55%

5~100

為適應不同布料設定後光眼的發射強度

Setting photo-eye through the fabric strength,to adapt to 
different fabrics

S19

前抬壓腳保留時間

Front foot presser lift 
retaining time

400

100~

2000 ms

前光眼感應到布時壓腳自動抬起維持時間

When front sensor feel the cloth, the foot presser lifter 
maintain time 

S20

後抬壓腳延遲啟動

Back foot presser lift start 
time

0

0~

2000 ms

腳踏板後踏壓腳回應的時間(毫秒)

The lift foot response time after latter foot 
pedal(millisecond)

S21

抬壓腳保護時間

Foot presser protection time

6

1~120s

手動抬壓腳持續多少時間後自動關閉壓腳輸出(秒)

Lifter the foot presser by hand some time then auto close 
foot presser output(second)

S22

放壓腳保護時間

Release foot presser 
protection time

20

20~

800 ms

壓腳釋放保護時間(毫秒)

The foot presser release protection time (millisecond)

S23

連續送布吸氣剪線

Continue feed cloth suction 
cutting line

0

0~1

0

:關閉

 1

:開啟

0:Close   1:open

S24

運轉中手動開關動作

Operate manual switch 
action

1

0~3

0

:電機運轉時按手動剪線不剪,

1

:可以剪

(

全手工模式時有效

)

2

:運行中禁止中光眼保護

3

:運行中禁止中後光眼保護

0: when motor is running, press knife switch the thread 
line is not cutting, 
1: Can Cut (under the manual mode)
2: when the machine is running, the middle sensor 
protect is prohibition 
3:when the machine is running, the middle and back  
sensor protect is prohibition 

S25

安全開關選擇

Safe switch choice

3

0~3

0

:關閉安全開關

  1

:縫台安全開關

      2

:壓腳安全開

    3

:縫台

+

壓腳安全開關開啟

0:Off safety switch   1:seam safety switch   2:foot safety 
switch   3: 

S26

切刀保留時間

The knife retaining time

25

1~

1000 ms

切刀動作時間(基本不用調整)

Cutting action time (basically no adjustment)

S27

介面恢復時間

Recover time

5

5~

100s

控制台在進入功能表後多少時間跳回主介面

After entering the control panel ,how much time to jump 
back to the main menu interface

S28

光眼模式(數量選擇)

Sensor mode (number 
choice)

2

1~2

1:

單光眼

  2:

雙光眼(※

:

第三光眼需要單獨開啟

s35

1:Single photo-eye  2:double photo-eye

S29

前光眼極性選擇

Front sensor polarity

0

0~1

0 : 

對射

  1 : 

反射

Opposite polarity opposite

S30

後光眼極性選擇

Back sensor polarity

0

0~1

0 : 

對射

  1 : 

反射

Opposite polarity opposite

S31

壓腳全力間

Foot presser full power time

180

10~

990 ms

壓腳全功率工作時的時間

Time of full power operation

S32

壓腳全力功率

Foot presser full  power

100

20~

100%

壓腳開始動作時,瞬間的輸出功率

When the foot starts to move, the instantaneous output 
power

S33

壓腳保持功率

Foot presser retaining power

20

10~
90%

壓腳抬起後維持住後的功率(不能超過

50

Pressure foot lift after the maintenance of the power to 
live (not more than 50)

P11

Summary of Contents for 700LQ ECA

Page 1: ...700LQ ECA ECB ELECTRONIC CONTROL PARAMETER MANUAL...

Page 2: ...CAUTIONS 2 INTRODUCTION OF DISPLAY SCREEN COMMON OPERATION 3 HOW TO ENTER PARAMETERS AND HOW MODLFY THE PARAMETERS 9 CONTROL BOX INTERFACE INSTRUCTION 15 TERMINAL SOCKET DESCRIPTION 16 ERROR CODE RESO...

Page 3: ...MAINTENANCE P1...

Page 4: ...n changing the needle threading or replacing the bottom line 5 During installation and removal service please turn off the power and pull the plug 6 Please turn off the power when turn lift sewing mac...

Page 5: ...lock 3 Value adjust key Parameter no Add key when modify the data 4 Parameter no Reduce key when modify the data 5 Left move key Left key The cursor moves to the left as the parameter entry is entered...

Page 6: ...under fully automatic semi automatic and free sewing press the pedal can not drive the sewing machine to work when the safety switch if off Full manual Press the pedal can be used to start the sewing...

Page 7: ...n delay close 0200 S13 middle suction delay start stitches 050 S14 middle suction close stitches 020 Thread cutting parameters S03 front thread cutting delay stitches 022 S04 back thread cutting delay...

Page 8: ...lock 5500 S51 Acceleration sensitivity 6 9 presser foot lifter thread tension releasing mode change key Single touch key to enter the thread tension releasing mode presser foot lifter mode option touc...

Page 9: ...ey enters the parameter adjustment Presser foot lifter parameter S19 front presser foot lifter remain time 0400 S20 back presser foot lifter delay start 0000 S21 presser foot lifter protect time 006 S...

Page 10: ...ime the LED light is off 11 F SENSOR Front sensor indicator When the sensor is blocked the light will be on when it is not blocked the light is not on if it is not blocked the light is on the sensor s...

Page 11: ...button to save parameters and quit system parameters Above is to enter method the details of speci c parameters describe as followings Factory default password 2014 2 2 touch the key directly into the...

Page 12: ...ction close stitches no 14 1 150 Account how many stitches begin to close former suction S07 Back suction start stitches no 2 1 150 After leaving latter photo eye how many stitches begin suck S08 The...

Page 13: ...Can Cut under the manual mode 2 when the machine is running the middle sensor protect is prohibition 3 when the machine is running the middle and back sensor protect is prohibition S25 Safe switch cho...

Page 14: ...008 1 100 S43 Net hole needle stitches 04 0 15 S44 Cloth choice 1 0 7 0 1 2 3 4 5 0 heavy materials 1 normal materials 2 light materials 3 transparent 4 large hole net 5 small hole net S45 Front senso...

Page 15: ...tart speed mode 1 0 1 0 P11 1 0 automatic according to P11 1 pedal P 08 Needle positio 0 0 1 0 1 0 Upper needle stop position 1 down needle stop position P 09 Machine stop auto foot presser lifting 0...

Page 16: ...o running 0 0 1 0 1 0 Closed 1 Open P 27 Auto runningn time 5 3 20 The time unit is Second P 28 Auto running stop time 2 2 20 The time unit is Second P 29 Control box version V2 07 P 30 Panel version...

Page 17: ...CONTROL BOX INTERFACE INSTRUCTION P15 PF...

Page 18: ...0R 7 LED 2 8 5V 3 9 5V 4 10 GND 5 3 3 5V 1 HX42000 4R 4 5V 2 4 2 5V 1 HX42000 2R 5 3 5V 1 GND HX42000 4R 4 2 6 4 5V 1 GND HX42000 6R 5 2 6 3 5V 7 4 1 30V HX42000 6R 5 2 30V 6 3 30V 8 2 1 30V HX42000 2...

Page 19: ...r signal line 2 Change the foot controller 3 Replace the foot controller ER 03 Motor phase signal error 1 2 3 1 Bad contact of nine pin plug 2 There is a large deviation in the installation of the mot...

Page 20: ...20v 1 The motor drive power supply voltage is too high the 220v power supply voltage exceeds the limit value ac310v or the load inertia is too large to the regenerative voltage exceeds the limit value...

Page 21: ...ding to categories as the followings 1 All sheathes exible hosing and plastic or non metal components 2 Electricity components switches or lighting components 3 Insulation materials rock wool and exib...

Page 22: ...The specification and or appearances of the equipment described in this instruction book parts list are subject to change because of modification which will without previous notice KZ08LQ U AUG 2021...

Reviews: