Siruba 700LQ ECA Manual Download Page 12

技術員系統參數清單:

Technician system parameter list

序號

System 

parameter 

list

功能說明

Function description

功能參數

預設值

Parameter 

default values

功能參數

範圍

 Parameter 

Adjustment 

range

參數說明

Parameter description

S01

針跡

  thread track

3

1

4

S02

兩感測器間針數

Stitch number between two 
sensors

20

1~150

設定兩個光眼之間的針數

Set stitch number between two sensors

S03

前剪線延時針數

Delay stitch number to cut 
thread after front sensors

022

0~150

後面光眼感應到布後延遲剪線的針數

Set delay stitch number after passing front sensors.Auto 
cut thread after stitchs

S04

雙光眼模式後剪線延遲針數

Delay stitch number to cut 
thread after two sensors

14

0~150

布離開第二光眼離開後延遲剪線的針數

Set delay stitch number after passing two sensors.Auto 
cut thread after stitchs

三光眼模式前剪線延遲針數

Delay stitch number to cut 
thread after three sensors

0

0~100

布離開第三

(

)

光眼離開後延遲剪線的針數

Set delay stitch number after passing two sensors.Auto 
cut thread after stitchs

S05

前吸延遲氣開啟針數

Delay stitch number for 
starting front air suction

2

1~150

布感應到第一個光眼後從第幾針開始吸氣

Set delay stitch number for starting front air suction after 

triggering first sensor

S06

前吸氣針數

Front suction close stitches 
no.

14

1~150

吸氣打開後,計數幾針後關閉吸氣

Account how many stitches begin to close former 
suction

S07

後吸氣延遲開啟針數

Back suction start stitches 
no.

2

1~150

離開後光眼後第幾針開始吸氣

After leaving latter photo-eye,how many stitches begin 
suck

S08

後吸氣延時關閉

The delay of back suction 
close

200

50~

5000 ms

布離開光眼後,計數幾毫秒後關閉吸氣

After leaving latter photo-eyes,count how many 
milliseconds off suction

S09

前松線延遲開啟針數

Front thread loose delay

00

0~150

無說明

S10

前松線針數

Front thread loose stitches

12

0~150

無說明

S11

後松線延遲開啟針數

Back thread loose start

00

0~150

無說明

S12

停車延遲針數

Machine stop delay stitches 
no.

002

1~150

後剪完線後多少針自動停車

How much stitches auto parking after trimmer

S13

中吸氣延遲開啟針數

Middle suction start stitches 
no.

50

1~250

中吸氣間隔針數

Middle suction interval stitches

S14

中吸氣針數

Middle suction close stitches 
no.

20

1~150

中吸氣針數

Middle suction stitches

S15

後剪光眼(第三光眼)延遲
檢測針數

The needle no. Of the delay 
of back cutting line

25

1~100

三光眼模式:布離開中光眼經過多少針後沒檢測到第三
光眼信號就開始剪線

Leave in the light eye after much after the needle cannot 
detect the third eye signal begins to cut the line

S16

前感測器回應時間

Front sensor respond time

40

1~

1000 ms

前面光眼感應到後回應的時間

The response time when former photo-eye sense

S17

前感測器靈敏度

Front sensor sensitivity 
degree

55%

5~100

為適應不同布料設定前光眼的發射強度

Setting photo-eye through the  fabric strength, to adapt 
to different fabrics

P10

Summary of Contents for 700LQ ECA

Page 1: ...700LQ ECA ECB ELECTRONIC CONTROL PARAMETER MANUAL...

Page 2: ...CAUTIONS 2 INTRODUCTION OF DISPLAY SCREEN COMMON OPERATION 3 HOW TO ENTER PARAMETERS AND HOW MODLFY THE PARAMETERS 9 CONTROL BOX INTERFACE INSTRUCTION 15 TERMINAL SOCKET DESCRIPTION 16 ERROR CODE RESO...

Page 3: ...MAINTENANCE P1...

Page 4: ...n changing the needle threading or replacing the bottom line 5 During installation and removal service please turn off the power and pull the plug 6 Please turn off the power when turn lift sewing mac...

Page 5: ...lock 3 Value adjust key Parameter no Add key when modify the data 4 Parameter no Reduce key when modify the data 5 Left move key Left key The cursor moves to the left as the parameter entry is entered...

Page 6: ...under fully automatic semi automatic and free sewing press the pedal can not drive the sewing machine to work when the safety switch if off Full manual Press the pedal can be used to start the sewing...

Page 7: ...n delay close 0200 S13 middle suction delay start stitches 050 S14 middle suction close stitches 020 Thread cutting parameters S03 front thread cutting delay stitches 022 S04 back thread cutting delay...

Page 8: ...lock 5500 S51 Acceleration sensitivity 6 9 presser foot lifter thread tension releasing mode change key Single touch key to enter the thread tension releasing mode presser foot lifter mode option touc...

Page 9: ...ey enters the parameter adjustment Presser foot lifter parameter S19 front presser foot lifter remain time 0400 S20 back presser foot lifter delay start 0000 S21 presser foot lifter protect time 006 S...

Page 10: ...ime the LED light is off 11 F SENSOR Front sensor indicator When the sensor is blocked the light will be on when it is not blocked the light is not on if it is not blocked the light is on the sensor s...

Page 11: ...button to save parameters and quit system parameters Above is to enter method the details of speci c parameters describe as followings Factory default password 2014 2 2 touch the key directly into the...

Page 12: ...ction close stitches no 14 1 150 Account how many stitches begin to close former suction S07 Back suction start stitches no 2 1 150 After leaving latter photo eye how many stitches begin suck S08 The...

Page 13: ...Can Cut under the manual mode 2 when the machine is running the middle sensor protect is prohibition 3 when the machine is running the middle and back sensor protect is prohibition S25 Safe switch cho...

Page 14: ...008 1 100 S43 Net hole needle stitches 04 0 15 S44 Cloth choice 1 0 7 0 1 2 3 4 5 0 heavy materials 1 normal materials 2 light materials 3 transparent 4 large hole net 5 small hole net S45 Front senso...

Page 15: ...tart speed mode 1 0 1 0 P11 1 0 automatic according to P11 1 pedal P 08 Needle positio 0 0 1 0 1 0 Upper needle stop position 1 down needle stop position P 09 Machine stop auto foot presser lifting 0...

Page 16: ...o running 0 0 1 0 1 0 Closed 1 Open P 27 Auto runningn time 5 3 20 The time unit is Second P 28 Auto running stop time 2 2 20 The time unit is Second P 29 Control box version V2 07 P 30 Panel version...

Page 17: ...CONTROL BOX INTERFACE INSTRUCTION P15 PF...

Page 18: ...0R 7 LED 2 8 5V 3 9 5V 4 10 GND 5 3 3 5V 1 HX42000 4R 4 5V 2 4 2 5V 1 HX42000 2R 5 3 5V 1 GND HX42000 4R 4 2 6 4 5V 1 GND HX42000 6R 5 2 6 3 5V 7 4 1 30V HX42000 6R 5 2 30V 6 3 30V 8 2 1 30V HX42000 2...

Page 19: ...r signal line 2 Change the foot controller 3 Replace the foot controller ER 03 Motor phase signal error 1 2 3 1 Bad contact of nine pin plug 2 There is a large deviation in the installation of the mot...

Page 20: ...20v 1 The motor drive power supply voltage is too high the 220v power supply voltage exceeds the limit value ac310v or the load inertia is too large to the regenerative voltage exceeds the limit value...