background image

  

7

rugs or carpets over it. The appliance can be
fitted  to  a  purpose  made  proprietary  class
“O” – 100°C or 150°C surround.

2.9

In particular  the finished  hearth  level 

MUST

extend 300mm in front of the vertical face of
the  fireplace  for  both  the  16”  and  18”
variants. The minimum width of the hearth is
650mm  for  the  16”  and  700mm  for  the  18”
version.

THE  APPLIANCE  MUST  NOT  STAND  ON
C O M B U S T I B L E  

M A T E R I A L S  

OR

CARPETS  OR  BE  FITTED  TO  A
COMBUSTIBLE WALL.

2.10

The  minimum  height  above  the  top  surface
of  the  hearth  for  any  projection  (e.g.  shelf
etc.)  150mm  deep  made  from  wood  or  any
other  combustible  material  is  766mm.  For
combustible  projections  above  150mm
depth,  add  12.5mm  to  the  above  clearance
for  every  25mm  of  additional  projection
depth.

2.10.A 

HOLE  IN  THE  WALL  APPLICATION

 The

appliance  can  be  used  in  a  no  hearth
application if  the installation complies to BS
5871-3:2005  and  appliance  is  installed  so
that the height from the base of the fireplace
opening  to  the  floor  is  no  less  then  300mm
as shown in Fig 3

2.11

Please  note  that  soft  wall  coverings  (e.g.
embossed vinyl’s etc.) are easily affected by
heat.  They  may,  therefore,  scorch  or
become discoloured when close to a heating
appliance.  Please  bear  this  in  mind  when
installing.

2.12

The  appliance 

MUST  NOT

 be  installed  in

any room which contains a bath or shower or
where steam is regularly present.

2.13

An extractor fan 

MUST  NOT

 be fitted  in the

same room  as  the  appliance  or  in  any  area
from  which  ventilation  is  taken  IF  IT  IS
LIKLEY  TO  AFFECT  THE 

SAFE

OPERATION  OF  THE  APPLIANCE.  If there
is  a  fan  in  such  a locality,  note  the  spillage
test requirements detailed on page 16.

2.14

VENTILATION REQUIREMENTS

For use in 

GB

 purpose-built ventilation is not

normally  required  for  600  model.  The 

1000

model 

REQUIRES

  ventilation  of  min  air

space 100mm x 100 mm
For  use  in 

I E

  ventilation  must  be  in

accordance with IS 813.

2.15

It  is  essential  that  all  decorative  fenders
have  a  minimum  open  area  of  50cm_  to
ensure  adequate  air  supply  for  correct
combustion  and  are  approved  for  use  with
this appliance.

3

CHECK CARTON CONTENTS

 

1  Fire Royal Burner Unit.

 

1

Set of fuel ceramic pieces

 

1

Pack of Granular Material

 

1

Battery pack 6 X AA, 1 X D cell

 

1

Remote Handset

 (

Remote Version Only

).

 

1

Instruction Manual.

 

1

Gather hood

 

1

Fixing kit

 

0  The adapter to 175mm tube is not
included

4

THE FIREPLACE

4.1 

FIREPLACE SIZE

Make  sure  that  the  fireplace  conforms  to
the  sizes  stated  in  2.2  of  General
Installation  Requirements  (refer  to  Figure
3).

 Figure 3

330 (M1000)

310 (M600)

1035 (M1000)

635 (M600)

563 (M600)

622 (M1000)

450 MIN

4.2

The  fireplace  opening  should  be  in  good
order and have a reasonably flat floor level
with the hearth.

4.2 

After  preparing  the  fireplace,  apply  a
lighted  match,  paper  or  smoke  match  to
the chimney opening. Observe the smoke.
If there is a definite flow into the opening,
continue with the installation. If there is not
a definite flow, pre-heat the chimney for a
few  minutes  and  re-check.  If  there  is  still
no  definite  flow,  the  chimney  may  need
attention. 

DO  NOT  FIT  THE  APPLIANCE

– SEEK EXPERT ADVICE.

5

GAS SUPPLY PIPE

A restrictor PTP elbow is provided for the
gas connection

NOTE:  The  supply  pipe  must  be  of  rigid  durable
material. Flexible pipe MUST NOT be used.

6

APPLIANCE INSTALLATION

6.2

Remove  the  gather  hood  this  is  placed  in
the  fire  box  up  side  down.  Remove  the

V-11-07

Summary of Contents for Fire Royal 1000

Page 1: ...E MANUAL REMOTE PLEASE KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE Our policy is constant development and improvement Strict accuracy of illustrations and specifications is not guaranteed Modifications to design and materials may be necessary subsequent to publication WINTHER BROWNE 75 Bilton Way Enfield London EN3 7ER Tel 0845 612 1893 Fax 0845 612 1894 V 11 07 eco ...

Page 2: ...______________ 5 FUEL BED ASSEMBLY _________________________________________ 5 INSTALLATION SECTION ______________________________________ 6 1 GENERAL DATA__________________________________________ 6 2 GENERAL INSTALLATION REQUIREMENTS ___________________ 6 3 CHECK CARTON CONTENTS _______________________________ 7 4 THE FIREPLACE _________________________________________ 7 5 GAS SUPPLY PIPE_______...

Page 3: ... 150mm DEEP MADE FROM WOOD OR ANY OTHER COMBUSTIBLE MATERIAL IS 766mm FOR COMBUSTIBLE PROJECTIONS ABOVE 150mm DEPTH ADD 12 5mm TO THE ABOVE CLEARANCE FOR EVERY 25mm OF ADDITIONAL PROJECTION DEPTH 9 NEVER THROW PAPER OR OTHER MATERIAL ONTO THE FIRE 10 IT SHOULD BE APPRECIATED THAT ALTHOUGH THIS APPLIANCE CONFORMS TO ALL THE REQUIRED STANDARDS IT IS A DECORATIVE FUEL EFFECT HEATING APPLIANCE WITH AN...

Page 4: ...ise to the HIGH position The fire will now ignite 2 To decrease the amount of flame push the control knob in slightly and turn to the LOW position The fire can now be used at any desired setting at any position between minimum LOW and maximum HIGH TO TURN OFF 1 Push in and turn the control knob clockwise to the OFF position to extinguish the flames and the pilot flame 2 If desired he pilot flame c...

Page 5: ...and follow the operating instructions on pages 4 and 5 The ODS is designed to shut off the gas supply to the burner if the oxygen content of the room falls below a certain level If it continues to operate then contact your installer to have the fire and flue system checked SERVICING AND MAINTENANCE If your fire requires servicing or maintenance please contact your supplier quoting the model name a...

Page 6: ...ent person and installed in accordance with the current edition of I S 813 Domestic Gas Installations and the current building regulations 2 2 The appliance can be used in the following openings A Fireplace recess built from components according to BS 1251 Open Fireplace Components The flue should be a class 1 type with a minimum effective height of 3 meters The Minimum depth of the opening 310mm ...

Page 7: ...locality note the spillage test requirements detailed on page 16 2 14 VENTILATION REQUIREMENTS For use in GB purpose built ventilation is not normally required for 600 model The 1000 model REQUIRES ventilation of min air space 100mm x 100 mm For use in I E ventilation must be in accordance with IS 813 2 15 It is essential that all decorative fenders have a minimum open area of 50cm_ to ensure adeq...

Page 8: ...pply and check for gas soundness with a suitable leak detection fluid see BS 6891 Please check all joints including the pilot assembly 6 6 FUEL BED ASSEMBLY Refer to the User s section for details 7 FUNCTIONAL CHECKS Remove the pressure test point sealing screw from the isolation elbow and attach a suitable pressure gauge Light the pilot and check the correct operation of the burner at all the fla...

Page 9: ...ace for replenishment 9 5 Please explain to the customer the purpose of the Oxygen Depletion System ODS and in particular the following a The ODS system operates if the Oxygen level in the room falls below safe levels usually due to interruption of the evacuation of combustion products i e a blocked chimney etc b Describe the restart procedures c Point out that on operation of the ODS system they ...

Page 10: ...the 8mm burner supply tube from the tap e Disconnect the 8mm gas inlet tube from the tap f Pull off the control knob g Remove the retaining nut from the front of the control panel The tap FSD ignition unit can now be removed and exchanged h Re assemble in the reverse order 11 MAINTENANCE SPARES During servicing and maintenance your appliance may need some replacement parts Here is a short list of ...

Page 11: ...unt of granular material in the burner tray See section 6 6 3 Try slight adjustments to the fuel effect pieces IGNITION FUNCTIONAL CHECK 1 NO See NO SPARK chart NO Consult the User s section in this manual and retry NO Check isolation tap and gas meter and retry NO Correct and retry NO Ther is a blockage in the system Check the inlet test point the mag valve seating and blow out any dirt from the ...

Page 12: ...assembly e g coal soot etc Check for fluff in the pilot aeration hole See figure 19 PILOT WILL NOT STAY LIT OR FIRE GOES OUT If the appliance goes out in use continually this may mean that the oxygen depletion sensor ODS has been activated The appliance should not be used until the cause has been found and rectified IGNITION FUNCTIONAL CHECK 2 NO Consult the User s section in this manual and retry...

Page 13: ...13 FIG 6 SCREWS SUPPLIED FLUE ADAPTER OPTION NOT INCLUDED GATHER HOOD CANOPY SCREWS SUPPLIED V 11 07 ...