4
USER’S SECTION
FUEL EFFECT
This fire in certain models is supplied with ceramic
fuel effect pieces to simulate a real fire and a
granular bed to provide flame distribution across
the bed. These items are safe to handle and they
are designed for easy re-fitting after removal
.
Gas consumption
Please refer to the general data on page 6 item 1
OPERATING INSTRUCTIONS -
Manual Version
Figure 1
OFF
IGNITION
HIGH
LOW
For your safety, the fire is fitted with a Flame
Supervision Device (FSD), which will shut off the
gas supply if for any reason the pilot is
extinguished. This device incorporates a fixed
probe, which senses heat from the pilot burner
flame. If the probe is cool, the device will prevent
any gas flow unless the control knob is pushed in
at the IGNITION position.
If for any reason the flames go out or if the fire has
been turned off for any reason, always WAIT FOR
3 MINUTES before attempting to relight.
TO LIGHT THE FIRE
1.
From the off position, SLOWLY push in
and turn the control knob anti-clockwise to
activate the spark at the IGNITION
position.
2.
Keep the control knob pressed in at this
position for approximately 10 – 20
seconds to allow the Flame Supervision
Device to warm.
3.
Release the control knob. The pilot should
remain lit independently.
SELECT THE BURNER FLAME LEVEL
NOTE: When first turned on the flames will appear
predominately blue. The ceramic bed will take time
to warm up.
1.
After lighting the pilot as described above,
turn the control knob anti-clockwise to the
HIGH position. The fire will now ignite.
2.
To decrease the amount of flame push the
control knob in slightly and turn to the
LOW position. The fire can now be used at
any desired setting at any position
between minimum (LOW) and maximum
(HIGH).
TO TURN OFF
1.
Push in and turn the control knob
clockwise to the OFF position to
extinguish the flames and the pilot flame.
2.
If desired he pilot flame can be left on to
make it quicker and easier to light the fire.
Although the pilot is using gas all the time
it is on, the amount used is minimal. To do
this turn the control knob to the IGNITION
position instead of the OFF position as
described above. If the fire is to be
switched OFF for long periods, it is
recommended that the control knob be
turned to the OFF position.
CLEANING
All cleaning
MUST
be carried out when the fire is
cold. NOTE: Heat is retained for some time after
the fire is switched OFF. Clean the surround and
fender parts with a slightly damp cloth and then
dry. Abrasive cleaners should NOT be used.
Normally the fire should only need dusting. Light
coatings of soot will usually be burnt off during the
normal operation of the fire. If however, particles of
mortar from the chimney accumulate these should
be removed from the coals and back brick by
dismantling them and cleaning with a soft brush
If soot or other foreign matter has become mixed
with the granular materials and cannot be removed
by hand, remove the contaminated layer and
replace with a clean layer. When levelling ensure
that none of the granules are pushed into the pilot
burner outlet.
If large pieces of debris are found any where in the
fireplace, the chimney and appliance should be
V-11-07