32
USES
33
PANEL OPENING
It is possible to open the cover panel of the gre-
ase filters by pulling it gently as shown in fig. 1.
The panel is fixed by 4 magnets, there are also 4
safety cables to be released to completely remo-
ve the panel from the product (fig. 2).
It is recommended to install the product at a ma-
ximum distance of 2000 - 2100 mm from the floor
level.
Before proceeding with the installation of the ap-
pliance, check that all the components are not
damaged, otherwise contact the dealer and do
not proceed with installation.
Use an air outlet pipe that has the maximum leng-
th of no more than 5 meters.
- Limit the number of bends in the canalization
since each bends reduces the suction efficien-
cy equivalent to 1 linear meter. (for example if
n°2 90°bends are used the length of the ducting
should not exceed 3 meters).
- Avoid drastic changes of direction.
- Use a duct with a constant diameter of 150mm
over the entire length.
-Use a material approved by standards and re-
gulations.