Dome Installation 

Page 21 

Note: 

After threading the cables, block the cable entry hole with the supplied sponge(s) to 

prevent insects from entering the tube. 

6.  Fix the outdoor tube adaptor to the straight tube with the supplied screws and washers. 

Then adjust the waterproof boot to the junction of the straight tube and the outdoor tube 
adaptor. 

7.  Connect the cables to the dome camera. Then attach the dome to the outdoor tube adaptor 

and fix them with the supplied screw. 

 

 

6.4

 

Wall Mount 

There are three types of wall mounts for the Siqura HSD620PRH and HSD621PRH dome camera. 

 

Mounting with a mini wall mount, as shown in the section Mini wall mount. 

 

Mounting with a gooseneck tube, as shown in the section Wall mounting with gooseneck 
tube. 

 

Mounting with a wall box, as shown in the section Wall box mounting. 

 

6.4.1

 

Mini wall mount 

Items Needed 

 

Dome camera 

 

Mini wall mount and other equipped items (optional accessory) 

 

Screws and screw anchors (not supplied) 

 

Indoor tube adaptor for the Siqura HSD620PRH and HSD621PRH (optional accessory) 

 

Waterproof boot (supplied with the indoor tube adaptor) 

Tools Needed 

 

Drill 

 

Screwdriver 

 

To mount the dome with the mini wall mount 

1.  Make a cable entry hole in the wall to recess the cables. Otherwise, cables can be threaded 

through the cable entry hole on the mount. 

2.  Thread the cables through the mini wall mount and out through either the cable entry hole 

in the wall or the hole in the mini wall mount. 

3.  Fix the wall mount to the wall with proper screws and screw anchors. 
4.  Attach the waterproof boot to the mini wall mount. 
5.  Thread the cables through the tube adaptor and lock it to the mini wall mount with the 

supplied screws and washers. 

At this point, the dome can be suspended from the mini wall mount using the safety wire. 

6.  Block the mount's cable entry hole.   

If the cable is threaded into the wall, block the hole in the mount with the supplied plate.   
If the cable is threaded through the neck of the wall mount, block the cable entry hole with 
the supplied sponge(s) to prevent insects from entering the tube. 

7.  Attach the lock screw plate to the dome plate with the supplied screw, as depicted in the 

section Ceiling mounting with a straight tube. 

8.  Adjust the waterproof boot to the junction of the mini wall mount and the indoor tube 

adaptor. 

9.  Connect the cables to the dome camera. Then attach the dome to the indoor tube adaptor 

and fasten them together with the supplied screw. 

 

Summary of Contents for HSD620PRH

Page 1: ...Siqura HSD620PRH 621PRH Pressurized IP PTZ Camera with Day Night WDR Installation Manual P R H...

Page 2: ...use other than that stated in this manual Although considerable care has been taken to ensure a correct and suitably comprehensive description of all relevant components the manual may nonetheless co...

Page 3: ...ements 13 4 6 2 Verifying Ethernet connectivity 13 4 6 3 Connecting Aligning and Mounting the Camera 14 5 PRESSURIZING THE CAMERA 17 5 1 PRESSURE SWITCH CALIBRATION 17 5 2 PRESSURIZING 18 6 DOME INSTA...

Page 4: ......

Page 5: ...fields of CCTV systems and components Electrical wiring and low voltage electrical connections Ethernet network technologies and Internet Protocol IP Windows environments Web browsers Video audio data...

Page 6: ...on Numbered list Step by step procedures You can follow these instructions to complete a specific task Special Bold Items you must select such as menu options command buttons or items in a list Emphas...

Page 7: ...ty precautions and warnings specified in this manual and that this unit be installed in locations accessible to trained service personnel only Safety Requirements The equipment described in this manua...

Page 8: ...discharge ESD can damage or destroy electronic components Proper precautions should be taken against ESD when opening the equipment 2 2 Cautions Handle the camera carefully Do not abuse the camera Avo...

Page 9: ...Directive 2002 96 EC Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By proper waste handling of this product you ensure th...

Page 10: ......

Page 11: ...ream support Dual H 264 MPEG 2 MPEG 4 and MJPEG 26x optical zoom 12x digital zoom Day Night with IR cut filter Back Light Compensation Wide Dynamic Range 400 second preset targeting 360 endless pannin...

Page 12: ...systems and allows the Siqura HSD620PRH and HSD621PRH to be integrated with other suppliers surveillance systems For more detailed information see the Technical Specifications appendix 3 3 Package Con...

Page 13: ...ystem Compatibility 13 Dome Cable Definition and Requirements 13 4 1 Preparing the Siqura HSD620PRH and HSD621PRH for Installation This preliminary installation procedure is for the Siqura HSD620PRH a...

Page 14: ...ese settings are preset to operate the camera with the IP hardware Changing the settings may make the camera inoperative using the IP connection Refer to the figure and table below for switch location...

Page 15: ...ation but do not change the default settings or some functions may not work properly Communication Switch Switch Description 1 RS 485 2 3 Termination 4 Line lock 5 System initialization Switch 5 is ma...

Page 16: ...configure the network adapter on the host PC 1 In the Control Panel open Network Connections 2 Right click the connection to be configured and select Properties 3 In the items list select Internet Pr...

Page 17: ...e at http www siqura com Registration is required 4 6 Dome Cable Definition and Requirements For operation the Siqura HSD620PRH and HSD621PRH cameras require either an Ethernet cable or an appropriate...

Page 18: ...e protocol and network switches connect the main cable to the base of the camera and make the appropriate connections To align mount the pressurized camera 1 Attach the cable harness to the camera Att...

Page 19: ...Dome Setup and Cable Connection Page 15 3 Attach the dome to the housing Align the dome Secure the dome 4 Connect the cable as follows IP connection configuration...

Page 20: ...Siqura HSD620PRH 621PRH Page 16 Cable connection in a mini wall mount...

Page 21: ...sensor Power up the unit The green LED located in the center of the camera bracket will turn on After 30 seconds the LED will begin to blink Press the red button located next to the LED LED will turn...

Page 22: ...Set the gauge or regulator from 10 to 20psi 7 to 1 4bar Place the air chuck on the tank valve and begin filling until pressure relief valve opens Open the relief valve Drain all air from the housing a...

Page 23: ...x 285 mm 14 4 x 11 2 x 11 2 in 6 2 Installation Scenarios Choose your installation scenario from the list below for complete instructions for performing that installation Important Whatever your scen...

Page 24: ...and HSD621PRH dome cameras is the straight tube mount Ceiling Mount straight tube The straight tube is available in lengths of 25 cm and 30 cm Items needed 5 Dome camera 6 Straight tube and other equi...

Page 25: ...iver To mount the dome with the mini wall mount 1 Make a cable entry hole in the wall to recess the cables Otherwise cables can be threaded through the cable entry hole on the mount 2 Thread the cable...

Page 26: ...cessory Tools Needed Drill Screwdriver To mount the dome with the gooseneck tube 1 Make a cable entry hole in the wall to recess the cables Otherwise cables can be threaded through the cable entry hol...

Page 27: ...essory Screws and screw anchors not supplied Indoor tube adaptor for the Siqura HSD620PRH and HSD621PRH optional accessory Waterproof boot supplied with the indoor tube adaptor Tools Needed Drill Scre...

Page 28: ...e Siqura HSD620PRH and HSD621PRH optional accessory Waterproof boot supplied with the indoor tube adaptor Screws and screw anchors for fixing the corner standard mounting plate not supplied Tools Need...

Page 29: ...the dome camera Then attach the dome to the indoor tube adaptor and fasten them together with the supplied screw Corner wall mounting corner standard mounting plate gooseneck tube mini wall mount indo...

Page 30: ...eck tube to the pole direct mounting with the supplied screws and washers 3 Attach the waterproof boot to the gooseneck tube 4 Thread the cables through the gooseneck tube and the tube adaptor After t...

Page 31: ...eneck tube to the pole box with the supplied screws and washers 3 Attach the waterproof boot to the gooseneck tube 4 Thread the cables through the gooseneck tube and the tube adaptor Note After thread...

Page 32: ......

Page 33: ...nce In This Chapter Mounting Accessories 29 Siqura HSD620PRH and HSD621PRH Accessories 33 7 1 Mounting Accessories All mounting accessories are optional To secure the camera to the tube or wall mount...

Page 34: ...2 lbs Gasket plate and cable gland for IP66 rated installations included PM05 Swan neck Mount White Iron Height 250 500 mm 9 8 19 7 in Diameter 50 mm 2 in 1 kg 2 2 lbs 1 8 kg 4 lbs CM01 250mm CM02 500...

Page 35: ...mm washer 4 spring washer 4 M8 16 screw 4 M8 nut 4 PM04 Pole Wide Box White Ivory 270 166 155 mm 10 6 6 5 6 1 in 3 2 kg 7 1 lbs Supplied with M8 16 screw 4 washer 4 spring washer 4 stainless steel str...

Page 36: ...e Direct Mounting White Ivory 270 170 60 mm 10 6 6 7 2 4 in Diameter 112 130 mm 4 4 5 in 1 kg 2 2 lbs Supplied with stainless steel straps 4 M8 16 screw 4 washer 4 ST01 Stainless Steel Straps For fixi...

Page 37: ...OR Input 220 230VAC Output 24VAC 72VA EU UK Note When wiring make sure the G Y wire Ground is inserted into the mid pin of the terminal block PA03 Power Adapter optional Input 110 115VAC Output 24VAC...

Page 38: ......

Page 39: ...m 3 4 119 mm Focus Mode Auto Manual White Balance Auto Manual Iris Control Auto Manual AGC Control Auto Manual Backlight Compensation On Off VIDEO Number of video streams 2x H 264 2x MPEG 4 MPEG 2 and...

Page 40: ...90 Manual Speed 0 5 90 s Presets 256 Preset Accuracy 0 100 Preset Speed 400 s Cruise 2 Sequence 8 Auto Pan 4 Privacy Mask 24 8 Black White Mosaic 3 levels Proportional Pan Tilt On Off Resume after pow...

Page 41: ...ure Continuous 45 C to 50 C 49 F to 122 F 60 C Max Heater activation N A 15 C 27 C 60 F 80 F Ingress protection IP67 Regulatory CE FCC RoHS Housing Polycarbonate glass filled Bubble Clear Polycarbonat...